background image

QUIETCOOLSYSTEMS.COM

13

WELCOME

INST

ALLA

TION

WIRING

OPERA

TION

W

ARRANTY

TEMPERATURE

• 

The settings you choose in this section will 

change what temperature the fan will come on at 

each set speed. 

• 

Tap on any speed to adjust the temperature for 

each speed. 

HUMIDITY

 

• 

Turn Fan Off:

 This is the humidity percentage 

that will cause the fan to turn off. For example, 

the factory setting is set at 90%, meaning the fan 

will turn off if the humidity in the attic is 90% or 

higher. Tap this setting if you would like to adjust 

the percentage. If you do not want this feature, 

you can select OFF at the top of the list. 

• 

Turn Fan On:

 This is the humidity percentage 

that will cause the fan to turn on, regardless if the 

temperature settings are not met. For example, 

the factory setting is set at 70%, meaning the fan 

will turn on if the humidity in the attic is higher 

than 70%, even if the temperature in the attic is 

below the temperature settings in the app. If you 

do not want this feature, you can select OFF at 

the top of the list. 

• 

Desired Speed: 

This is the speed the fan will use 

if the humidity causes the fan to turn on.

These settings will be saved into the memory of 

the Hub meaning all settings will sync between any 

additional devices you pair to the Hub.

Click Done to complete Fan Setup. You can always 

access these settings again from the Settings option 

on the Fan Control Page.

Summary of Contents for AFG SMT PRO-2.0

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE SMART ATTIC GABLE FAN AFG SMT PRO 2 0 AFG SMT PRO 3 0 AFG SMT ES 3 0...

Page 2: ...1 PHONE 1 888 QUIETCOOL WEBSITE WWW QUIETCOOLSYSTEMS COM WARNINGS CAUTION This unit has an unguarded impeller Do not use in locations readily accessible to people or animals CAUTION Do not operate any...

Page 3: ...emperatures for the multiple speeds of the fan setup presets for the different seasons of the year and even operate your fan on a timer QuietCool Attic Fans work almost everywhere anytime During the s...

Page 4: ...or effectively as it could with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractor...

Page 5: ...Mount The AFG can be mounted on a wide louver but additional mounting steps must be taken in order for the fan to work properly As shown in Figure 2 1B two additional boards must be fastened to the bo...

Page 6: ...n the attic fan cylinder causing air to cycle in and out around the vent 1 Take the vent cover and match it to one of the sides around the attic fan housing 2 Using the two provided screws attach each...

Page 7: ...fan to the white wire from the Hub 3 Connect the black wire from the fan to the blue wire on the Hub 4 Connect the red wire from the fan to the red wire on the Hub 5 Cap the yellow wire from the Hub 6...

Page 8: ...the power cord to the ground screw in the Hub 7 Set the dip switch positions inside the Hub as shown in Figure C 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make...

Page 9: ...shown below when the Test button is pressed Two Speed Fan blink three times every 2 seconds on HIGH blink once every 2 seconds on LOW Three Speed Fan blink three times every 2 seconds on HIGH blink t...

Page 10: ...app and is presented as soon as the app is opened If you have not yet paired your phone to your Hub it will state SETUP REQUIRED If you have paired your phone to your Hub it will show a picture of th...

Page 11: ...he different modes of the fan and get to the Fan Settings page FAN SETTINGS PAGE This page is used to adjust the settings of the fan You can quickly change the Fan Name check if the speeds are set pro...

Page 12: ...rations Tap on the fan to start the setup process Once you tap on the fan you will be taken to the Fan Setup page On this page you will be able to change the following settings Fan Name Fan Model Seri...

Page 13: ...top of the list Turn Fan On This is the humidity percentage that will cause the fan to turn on regardless if the temperature settings are not met For example the factory setting is set at 70 meaning t...

Page 14: ...nto the Fan Settings page and adjust the settings that you setup in the first step TIMER MODE Timer Mode is a simple way to turn your attic fan on for a set amount of time at a set speed To activate T...

Page 15: ...fan will not turn on or if it is already running the fan will shut off If the humidity in the attic is below the Turn Fan Off humidity setting the second paramater that is checked is the Attic Tempera...

Page 16: ...t is already paired to the Fan Hub If you do not have any devices that are currently paired to the Fan Hub you will have to press the physical Pair button In the Fan Settings page tap Enter Pair Mode...

Page 17: ...device version as well as what the available version is If there is an update available you will be able to tap the Update button Once you tap Update an alert will popup asking you to type in your Wi...

Page 18: ...will need to disconnect power make your adjustment inside the hub and then reconnect power CAN YOU CONNECT THE ATTIC FAN SMART CONTROL TO A SMART HOME SYSTEM LIKE ALEXA GOOGLE HOME OR APPLE HOMEKIT No...

Page 19: ...QUIETCOOLSYSTEMS COM 19 WELCOME INSTALLATION WIRING OPERATION WARRANTY...

Page 20: ...1 888 QUIETCOOL 20...

Page 21: ...QUIETCOOLSYSTEMS COM 21 WELCOME INSTALLATION WIRING OPERATION WARRANTY...