WHAT IS THE RANGE?

The RF Switch and RF Hub have a range restriction of 100ft.

WHAT HAPPENS IF I LOSE THE RF SWITCH?

If you lose or damage an RF Switch you will need to purchase another and re-pair the new one to the  

RF Hub.

CAN YOU CONTROL MULTIPLE FANS WITH A SINGLE SWITCH?

No. You can only control one RF Hub per switch.

         

HOW LONG DO THE BATTERIES LAST?

Up-to one year.

WHY ARE ALL MY LIGHTS SOLID ON THE HUB AND NOTHING IS WORKING?

If you’re experiencing solid lights on the hub then it is an indication that your DIP switches are not in the  

correct position. Disconnect power, adjust your DIP switches, and the only light that should be lit is your  

RED power light.

HOW DO I CHANGE THE DIP SWITCH TO THE CORRECT SPEED OF MY FAN?

You will need to disconnect power, make your adjustment inside the hub, and then reconnect power.

CAN YOU CONNECT THE RF CONTROL TO A SMART HOME SYSTEM LIKE ALEXA, 

GOOGLE HOME, OR APPLE HOMEKIT?

No, in the current configuration the RF Control cannot connect to a smart home system. There are  

systems on the market that take RF signal and translate them to a smart home system, but they have  

not been tested and may not work reliably.

4.3  WHEN TO RUN A QUIETCOOL WHOLE HOUSE FAN

 

Anytime it is cooler outside than the inside of your home, the system will work effectively. In the summer 

this normally happens in the late afternoon to early evening, through to the next morning. We recommend 

running your fan through the evening. If you have a multi-speed fan, you will get the best cooling effect 

when you turn the fan on low after desired cooling occurs and let it run throughout the night.

QuietCool can also be used in the winter to heat your home during the day and exhuast the pollutants 

inside your home.

Summary of Contents for RM WHF-4.0

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE ROOF MOUNT WHOLE HOUSE FAN RM WHF 4 0...

Page 2: ...9 3 WIRING 11 3 1 RM Whole House Fan Wiring 11 3 2 Fan Hub LED Indicators 12 3 3 Pairing the Wall Switch 13 3 4 Finding a Location forthe Wall Switch 13 3 5 Installing the Wall Switch 14 4 SYSTEM OPE...

Page 3: ...homes with a flat roof or homes with a sealed attic 1 2 FEATURES Ultra Energy Efficient Electronically Commutated Motor ECM Patent Pending Built in USA 15 Year Warranty Included RF Wireless Control K...

Page 4: ...empt to service the product 8 SAFETY PRECAUTIONS Do not install the fan in wet or windy conditions Tie off both yourself and your equipment when working on steep pitched roofs to avoid falls Wear safe...

Page 5: ...ist spacing is required for each installation type IMPORTANT If you are installing the RM WHF 4 0 PL skip to section 2 5 on pg 9 IMPORTANT Before installing the RM WHF 4 0 DB you will need to find the...

Page 6: ...sition Using a roofing knife cut a 4 inch horizontal slit in the shingles at the 9 o clock and 3 o clock positions of the hole allowing the fan s flashing to slide underneath the shingles 6 Apply weat...

Page 7: ...making sure that you have at least 2 inches of clearance all around it While holding the template in place mark its outline with a pencil See Figure 2 2C 6 Using a drywall saw or similar device cut o...

Page 8: ...ady to put your grille core back in place simply push it right into place and it will snap in tight 2 3 INSTALLING THE RM WHF 4 0 DG1 Use the following instructions to finish the installation of your...

Page 9: ...tion for your damper grilles Make sure the fan is equally centered between the two damper grille locations Make sure the damper grilles are installed in the same joist bay as the fan 2 When you have c...

Page 10: ...and will seal nice and tight 6 Position the fan over the circle fan hole in the plenum box Using the supplied self tapping screws with rubber bonded washers attach the fan unit to the plenum box Be s...

Page 11: ...ack wire from the power source to the black wire from the Hub 2 Connect the white wire from the power source and the white wire on the fan to the white wire from the Hub 3 Connect the red wire from th...

Page 12: ...AIR INDICATOR The Pair LED indicator will light up when making pair operations Please see below for details on pairing NOTES ON OPERATION If the Dip Switch is not configured correctly all the indicato...

Page 13: ...ators will be blinking indicating successful pairing Press the Wall Switch button again the speed indicators will go out and it will display the current fan status Press the Timer button to test the W...

Page 14: ...the plate onto the drywall through the four mounting holes 1 2 4 8 12 H M L 1 2 4 8 12 H M L 4 SYSTEM OPERATING INSTRUCTIONS 4 1 OPERATING THE WALL SWITCH TIMER BUTTON The top button on the switch con...

Page 15: ...In order for the fan to run a Timer selection MUST be made When the Timer status is off no LED indicators lit you can still change the Speed setting The Speed setting will take effect once the Timer...

Page 16: ...t power make your adjustment inside the hub and then reconnect power CAN YOU CONNECT THE RF CONTROL TO A SMART HOME SYSTEM LIKE ALEXA GOOGLE HOME OR APPLE HOMEKIT No in the current configuration the R...

Page 17: ...r home to prepare for bedtime Then when it s time for bed you should close all the windows in your main living space but leave the windows in your occupied bedrooms open This will provide each room wi...

Page 18: ...program is unlimited This means you can refer as many people as you like Best of all both you and your friend will earn 25 for each whole house fan that your friend installs QuietCoolSystems com refer...

Page 19: ...pment or any malfunction thereof 2 Cost of service calls to diagnose the cause of problems or the labor charge to un install any components 3 Product failure or damage due to faulty installation abuse...

Page 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 4 16 20...

Reviews: