background image

1-888-QUIETCOOL 

8

8.  Using the included drywall screws, fasten the damper box 

to the drywall and the joist in the attic. 

(See Figure 2.2E)

 

NOTE: 

Remember that you must fasten the damper 

box to the ceiling joists AND drywall. The purpose of 

this is to make sure the damper box stays in place when 

you are screwing in the grille. If you do not fasten the 

damper box to the drywall, the damper box will not stay 

in place when attempting to screw in the grille. (See 

Figure 2.2F)

9.  Remove the removable ceiling grille and screws from its 

packaging. Center the grille over the damper box. Install 

the grille with the white screws provided by screwing 

through the drywall into the flange of the damper box. 

(See 

Figure 2.2G) 

 

NOTE: 

To remove grille core for cleaning, use the 

provided grille removal tool in the corners of the grille 

core. When removing the grille, make sure to hold the 

core in place so it does not fall. When ready to put your 

grille core back in place, simply push it right into place, 

and it will snap in tight.

2.3  INSTALLING THE RM WHF-4.0-DG1

 

Use the following instructions to finish the installation of your accessory kit.

  These instructions are for installing the RM WHF-4.0 with 22” x 22”damper grille.

  IMPORTANT:

 The RM WHF-4.0-DG1 will only fit 24” on center ceiling joists.

1.  Using a stud finder, find and measure your ceiling joists and determine the location for your damper 

grille. Make sure the damper grille is installed in the same joist bay as the fan.

2.  When you have chosen your exact spot, place the provided template on the spot and make sure that 

you have at least 2 inches of clearance all around it. While holding the template in place, mark its 

outline with a pencil. 

(See Figure 2.3A)

 

3.  Using a drywall saw or similar device, cut out the hole in the ceiling. 

(See Figure 2.3B)

4.  Remove the damper grille and screws from its packaging. Place the grille in the ceiling cutout. Install 

the grille with the white screws provided by screwing through the drywall. 

(See Figure 2.3C)

!

!

!!

!!

Figure 2.2E

Figure 2.2F

Figure 2.2G

Summary of Contents for RM WHF-4.0

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE ROOF MOUNT WHOLE HOUSE FAN RM WHF 4 0...

Page 2: ...9 3 WIRING 11 3 1 RM Whole House Fan Wiring 11 3 2 Fan Hub LED Indicators 12 3 3 Pairing the Wall Switch 13 3 4 Finding a Location forthe Wall Switch 13 3 5 Installing the Wall Switch 14 4 SYSTEM OPE...

Page 3: ...homes with a flat roof or homes with a sealed attic 1 2 FEATURES Ultra Energy Efficient Electronically Commutated Motor ECM Patent Pending Built in USA 15 Year Warranty Included RF Wireless Control K...

Page 4: ...empt to service the product 8 SAFETY PRECAUTIONS Do not install the fan in wet or windy conditions Tie off both yourself and your equipment when working on steep pitched roofs to avoid falls Wear safe...

Page 5: ...ist spacing is required for each installation type IMPORTANT If you are installing the RM WHF 4 0 PL skip to section 2 5 on pg 9 IMPORTANT Before installing the RM WHF 4 0 DB you will need to find the...

Page 6: ...sition Using a roofing knife cut a 4 inch horizontal slit in the shingles at the 9 o clock and 3 o clock positions of the hole allowing the fan s flashing to slide underneath the shingles 6 Apply weat...

Page 7: ...making sure that you have at least 2 inches of clearance all around it While holding the template in place mark its outline with a pencil See Figure 2 2C 6 Using a drywall saw or similar device cut o...

Page 8: ...ady to put your grille core back in place simply push it right into place and it will snap in tight 2 3 INSTALLING THE RM WHF 4 0 DG1 Use the following instructions to finish the installation of your...

Page 9: ...tion for your damper grilles Make sure the fan is equally centered between the two damper grille locations Make sure the damper grilles are installed in the same joist bay as the fan 2 When you have c...

Page 10: ...and will seal nice and tight 6 Position the fan over the circle fan hole in the plenum box Using the supplied self tapping screws with rubber bonded washers attach the fan unit to the plenum box Be s...

Page 11: ...ack wire from the power source to the black wire from the Hub 2 Connect the white wire from the power source and the white wire on the fan to the white wire from the Hub 3 Connect the red wire from th...

Page 12: ...AIR INDICATOR The Pair LED indicator will light up when making pair operations Please see below for details on pairing NOTES ON OPERATION If the Dip Switch is not configured correctly all the indicato...

Page 13: ...ators will be blinking indicating successful pairing Press the Wall Switch button again the speed indicators will go out and it will display the current fan status Press the Timer button to test the W...

Page 14: ...the plate onto the drywall through the four mounting holes 1 2 4 8 12 H M L 1 2 4 8 12 H M L 4 SYSTEM OPERATING INSTRUCTIONS 4 1 OPERATING THE WALL SWITCH TIMER BUTTON The top button on the switch con...

Page 15: ...In order for the fan to run a Timer selection MUST be made When the Timer status is off no LED indicators lit you can still change the Speed setting The Speed setting will take effect once the Timer...

Page 16: ...t power make your adjustment inside the hub and then reconnect power CAN YOU CONNECT THE RF CONTROL TO A SMART HOME SYSTEM LIKE ALEXA GOOGLE HOME OR APPLE HOMEKIT No in the current configuration the R...

Page 17: ...r home to prepare for bedtime Then when it s time for bed you should close all the windows in your main living space but leave the windows in your occupied bedrooms open This will provide each room wi...

Page 18: ...program is unlimited This means you can refer as many people as you like Best of all both you and your friend will earn 25 for each whole house fan that your friend installs QuietCoolSystems com refer...

Page 19: ...pment or any malfunction thereof 2 Cost of service calls to diagnose the cause of problems or the labor charge to un install any components 3 Product failure or damage due to faulty installation abuse...

Page 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 4 16 20...

Reviews: