background image

QUIETCOOLSYSTEMS.COM

19

WELCOME

INST

ALLA

TION

WIRING

OPERA

TION

W

ARRANTY

15 YEAR LIMITED W

ARRANT

Y

QC STEAL

TH PRO LINE Whole House F

ans

WHOLE HOUSE FANS LIMITED WARRANTY

QC Manufacturing Inc. extends this warranty to the original purchaser of the following  

QuietCool Stealth Pro Line Models - QC STL PRO-1.5X, QC STL PRO-2.5X, QC STL PRO-3.3X,  

QC STL PRO-4.8X, QC STL PRO-5.5X, QC STL PRO-6.0X, and QC STL PRO-7.0X - installed and 

used in a residence under normal conditions within the United States:

A. 

Fifteen year coverage applies to the QuietCool motor fan assembly. At our option we 

will repair or replace any part of the assembly should it fail to operate during the first 

fifteen years from the date of original purchase.

B. 

One year coverage for all other components including grilles, housings, controls and 

accessories furnished by QC Manufacturing, Inc. At our option we will repair or replace 

any part which fails as a result of defective material or workmanship during the first year 

from the original date of purchase.

C. 

This warranty does not cover any of the following:

 

1.  Accidental or consequential damage resulting from the operation of  

our equipment or any malfunction thereof.

2.  Cost of service calls to diagnose the cause of problems or the labor  

charge to un-install any components.

3.  Product failure or damage due to faulty installation, abuse, misuse,  

unauthorized alteration to factory specs, lack of maintenance, or  

transportation damage.

4.  Shipping or postage for warranty claims.

D. 

To obtain service under this warranty, first contact the dealer where you purchased 

the equipment. If you are unable to find or reach your dealer, contact Customer Service 

at QC Manufacturing, Inc. In order to process a warranty claim, you must have your  

serial number as well as your proof of purchase. QC Manufacturing, Inc. will not process 

a warranty claim without a serial number. Your serial number is located on the fan  

motorhead as well as on the back of this Owner’s Guide.

This warranty is the only warranty extended by QC Manufacturing, Inc. to purchasers or suppliers of our equipment. QC Manufacturing Inc. 

disclaims all other warranties, express or implied, that arise by operation of the law. Where consumer may have additional warranty rights in 

accordance with federal and state law, such rights shall supersede those stated herein.

QC Manufacturing, Inc. Customer Service

26040 Ynez Rd.

Temecula, CA 92591

www.QuietCoolSystems.com

951-325-6340

Rev. 8-31-20

Summary of Contents for STEALTH PRO-1.5X

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE STEALTH PRO X WHOLE HOUSE FAN...

Page 2: ...TED IMPORTANT READ BEFORE INSTALL 8 3 INSTALLATION 10 3 1 Installing QuietCool 10 3 2 Installing Vertical Adapter 12 4 WIRING 13 4 1 Single Speed Wiring QC STL PRO 1 5X 13 4 2 Two Speed Wiring QC STL...

Page 3: ...equivalent to a loud vacuum cleaner running The QuietCool system uses a cutting edge patented design to get our sound levels down to a respectable level Our fans suspend in the attic and use an acoust...

Page 4: ...arly evening is spent in the kitchen or family room area Assuming this to be true this is where you would want to start the cooling process Begin opening a few windows in the area you are going to be...

Page 5: ...healthier If you have any trouble installing or operating your new QuietCool whole house fan or for more tips on running the QuietCool please visit our website www QuietCoolSystems com or call us at...

Page 6: ...obstruction F HIGH PERFORMANCE ACOUSTICAL DUCTING Noise dampening technology with insulated ducting that is used to separate the Steel Housing from the living space G AIRTIGHT DAMPER BOX Damper Box w...

Page 7: ...ould with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractors can add extra ventin...

Page 8: ...Care should be taken to avoid backdrafting combustion appliances that are installed in the conditioned space Whole house fans are capable of pulling large quantities of air from the home particularly...

Page 9: ...ST your QuietCool unit before installation using the included power cord If the fan does not work call us immediately SPECIAL INSTRUCTIONS TO CONTRACTORS 1 DO NOT take the Owner s Guide with you after...

Page 10: ...pencil 4 Using a drywall saw or similar device cut out the hole in the ceiling TIP If your attic is very tight you may want to wire your QuietCool motor housing before bringing it into the attic Plea...

Page 11: ...fasten the damper box to both the drywall and the joist in the attic NOTE Remember that you must fasten the damper box to the ceiling joists AND drywall The purpose of this is to make sure the damper...

Page 12: ...side of the vertical adapter Place the vertical adapter with the T side up onto the damper box with the side that has only two flanges flush on the damper box 2 If you have studs spaced at 16 on cent...

Page 13: ...ard wire the fan or it is required by your local building codes please follow the wiring instructions below WELCOME INSTALLATION WIRING OPERATION WARRANTY 4 1 SINGLE SPEED WIRING FOR QC STL PRO 1 5X 1...

Page 14: ...ft of the switch Finish up the installation of the timer and switch and switch cover plate 7 Begin wiring the your fan by opening up the handy box Take off the wire nuts within the handy box Detach th...

Page 15: ...Feed the 2 wire Romex from your timer into the handy box Feed the 2 wire Romex from your power source into the handy box STL PRO 2 5X Wiring see Figure 4 2B Feed the 2 wire Romex from your switch into...

Page 16: ...Figure 4 3A on page 17 NOTE With a pair of needle nose pliers break the bus on the switch The bus is located on the left between the two black screws With a little finesse it is very simple to remove...

Page 17: ...Tie the three bare copper wires and the two green ground wires together 10 Carefully reinstall the handy box cover Power Timer Tie All Ground Bare Copper Wires Together Whole House Fan 14 2 Wire 14 2...

Page 18: ...ly When the HIGH LOW OFF Switch is in the middle position the fan will be off regardless of the setting on the Timer With the switch in the top position the fan will be on HIGH With the switch in the...

Page 19: ...the operation of our equipment or any malfunction thereof 2 Cost of service calls to diagnose the cause of problems or the labor charge to un install any components 3 Product failure or damage due to...

Page 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 3 11 21...

Reviews: