When installing the unit, consideration must be given to
the proper location. The location selected should be as
close to the vent pipe termination outside the building,
and as centralized with the water piping system as
possible.
■
A minimum clearance of 4" must be allowed for access
to replaceable parts such as the thermostats, drain
valve and relief valve.
■
As the gas boiler is to be installed indoors, they shall not
be installed outdoors, such as in the porch.
■
Do not install boiler on a combustible wall or in a high
humidity location.
■
WARRANTY WILL BE CONSIDERED VOID IF THIS EQUIPMENT IS INSTALLED BY ANYONE OTHER THAN A
QUALIFIED, TRAINED AND LICENSED (WHERE APPLICABLE ) HEATING TECHNICIAN.
■
QUIETSIDE CORPORATION IS NOT RESPONSIBLE FOR PROBLEMS OR DAMAGE CAUSED BY IMPROPER
INSTALLATION INCONSISTENT WITH THIS MANUAL.
■
THE INSTALLING CONTRACTOR MUST INSTRUCT THE OWNER ON THE FULL OPERATION OF THIS PRODUCT.
■
THE INSTALLING CONTRACTOR MUST GIVE THE OWNER THE APPORPRIATE WARRANTY CERTIFICATE AFTER
THE INSTALLATION HAS BEEN COMPLETED.
There is a risk in using fuel burning appliances in rooms
or areas where gasoline, other flammable liquids or
engine driven equipment or vehicles are stored, operate or
repaired. Flammable vapors are heavy and travel along
the floor and may be ignited by the igniter or main burner
flames causing fire or explosion. Some local codes permit
operation of gas appliances if installed 18-inches or more
above the floor. This may reduce the risk if location in
such an area cannot be avoided.
Flammable items, pressurized containers or any other
potential fire hazardous articles must never be placed on
or adjacent to the boiler.
Open containers of flammable material should not be
stored or used in the same room with the boiler.
The units are released from our facility specially
packaged to prevent handling damage and
contamination in transit. Dropping or throwing the boilers
or moving them while outside of their shipping container
may cause damage or internal contamination by any
moisture remaining after testing. Do not stand the
boilers up by resting on the piping connections.
■
Never locate the unit outdoors,
Never locate the unit outdoors,
Never locate the unit outdoors,
Never locate the unit outdoors,
such as an open porch patio
or exposed to the wind, rain
snow and cold
temperatures.
Special consideration must
be given to where theventing will terminate outdoors.
■
Do not locate the unit in an equipment room that has
an exhaust fan.
■
Install the unit securely on any non-combustible wall
that is capable of supporting the 90 lbs weight of this
equipment.
■
Maintain an 6" clearance to the left and right of unit,
including 6" clearance in front of the unit for safety
inspections and future access.
■
Do not install unit in an underground or semi-
underground location unless using the model FF or
SCF 9 flue kit.