                                                                      22

22

22

22

About the FR-5 Thermostat

About the FR-5 Thermostat

About the FR-5 Thermostat

About the FR-5 Thermostat

  Quietside offers new and improved ways of getting the

best comfort from your new unit.

   The FR-5 thermostat is an advanced, multi-function

room controller that features a direct-readout L.E.D.
panel giving you accurate temperature control of your
environment as well as displaying information about
the performance and condition of your hydronic
heating system.

 There are two ways of sensing temperature for the

purpose of heating your home ; the most common is
simply by sensing the air temperature within the main
living area, typically where you spend the most time.
The other is by sensing the exact temperature of the
heating water delivered by the unit.

  With the FR-5 thermostat, both of these methods are

available to you. Now you can choose the simplicity of
setting your temperature by air(maintaining room
temperature) or the convenience and comfort of
setting your temperature by water(maintaining a
constant heating-water temperature).

 The temperature of the air within the living space of

the home can vary from five to ten degrees. It is
difficult to sense the exact temperatures of all areas
within the home when the thermostat is located in just
one room.

  Well-insulated homes of average design and families

with active lifestyles should find that setting the
thermostat to the air temperature-sensing function will
provide the best comfort.

 Other homes with unusually high ceilings,

inadequate insulation, leaky windows, long drafty
hallways or simply have people who tend to feel
drafts and chills more than others could find that
setting the thermostat to the water temperature-
sensing function will provide the best comfort. We
suggest trying them both.

[The Air Temperature Mode]

[The Air Temperature Mode]

[The Air Temperature Mode]

[The Air Temperature Mode]
 

The QVM 9 hydronic

 heating

system has built-in artificial

intelligence. In the air

 sensing

mode, the FR-5 thermostat
is busy tracking the room
set-temperature.
  By incorporating the use of
a pre-programmed microchip, the QVM 9 hydronic
heating system accurately adjusts the modulating
combustion process to best suit the changing needs of
the home.

[The Water Temperature Mode]

[The Water Temperature Mode]

[The Water Temperature Mode]

[The Water Temperature Mode]
 In the water-sensing mode,

the FR-5

 thermostat 

works

with the unit to

 maintain a

constant water temperature

condition. There is no

 sensing

of room temperature in the
water temperature sensing
mode of operating and
 therefore, small adjustments and fine-tuning will need
to be made from time to time.

[Energy Saving Mode

[Energy Saving Mode

[Energy Saving Mode

[Energy Saving Mode]

]]

]

 In winter, if you

re leaving

for work or plan to be

 away

for several hours or 

several

days, you can

 select the

unoccupied (Away from

Home Saving)

 mode to

reduce energy costs. During

these periods when the

 home is

vacant, you can program the
thermostat to operate the unit in a 

stand-by

 mode

where the unit will cease to operate in the normal heating
function. In stand-by, the thermostat tells the unit to
only operate for very brief intervals; for the period you
have selected(anywhere from 0 to 4 hours). 

When you

return

. Select the preferred temperature and press the

heating mode button.
 On the following pages you will find the FR-5 operating
instructions describing how to operate this device add
convenience to your life while keeping you and your
home more comfortable.

Water Temp.

Average(

)

Advantages of the Model FR-5 Thermostat

Advantages of the Model FR-5 Thermostat

Advantages of the Model FR-5 Thermostat

Advantages of the Model FR-5 Thermostat

Summary of Contents for 090W1-NG

Page 1: ...a a a a at t t t t t t ti i i i i i i in n n n n n n ng g g g g g g g S S S S S S S Sy y y y y y y ys s s s s s s st t t t t t t te e e e e e e em m m m m m m m Homeowner s Book and Installation Manua...

Page 2: ...ese buildups in the plate heat exchanger is not covered under the terms of this warranty This Warranty Does Not Cover 1 Installations by other than qualified heating contractors 2 Installations of equ...

Page 3: ...rsonal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Extinguish any open flame Do not try to light any applia...

Page 4: ...onnections 16 Installation of the Flue 18 Draining Condensed Water 21 About the FR 5 Thermostat 22 Installation of the Thermostat 23 Using the Room Thermostat FR 5 24 Test Operation and Checks 28 Rout...

Page 5: ...sidential Gas Hydronic Heating System QVM 9 Series 2 2 2 2 Identifying the Components Identifying the Components Identifying the Components Identifying the Components Model QVM 9 090W1 NG Model QVM 9...

Page 6: ...ICHAUTOMATICALLYLIGHTSTHEBURNER DONOTTRYTOLIGHTTHEBURNERBYHAND 9 TURNKNOBOFGASVALVETO OFF POSITION 6 WAIT AFEW MINUTES TO CLEAR OUT ANY GAS THEN SMELL FORGAS INCLUDINGNEARTHEFLOOR IF YOU DON TSMELLGAS...

Page 7: ...Low Water Level Safety 7 Low Water Level Safety The water level in the heat exchanger is continuously monitored to prevent the boiler from operating if there is no water or a restricted flow of water...

Page 8: ...atural gas to propane CAN ONLY BE PERFORMED CAN ONLY BE PERFORMED CAN ONLY BE PERFORMED CAN ONLY BE PERFORMED by a trained technician using approved QUIETSIDE parts In winter season the boiler should...

Page 9: ...of Scalds Risk of Scalds Risk of Scalds Risk of Scalds USE ANTI SCALD USE ANTI SCALD USE ANTI SCALD USE ANTI SCALD VALVE S VALVE S VALVE S VALVE S IN HOT WATER SYSTEM TO REDUCE THE RISKS OF SCALDING A...

Page 10: ...on demand There is no storage tank to hold hot water when there is no use for it The QVM 9 will only produce hot water when you use it instantaneously The modulating gas burner allows water to heat up...

Page 11: ...as become blocked 11 Smart Re 11 Smart Re 11 Smart Re 11 Smart Re Start Start Start Start Should the unit s flame fail due to strong winds or low gas pressure the unit will automatically restart In co...

Page 12: ...t Protection Overheat Protection Overheating burners or heat exchangers will automatically cut off the gas supply 7 7 7 7 Low Water Level Safety Low Water Level Safety Low Water Level Safety Low Water...

Page 13: ...or your dealer Use the Use the Use the Use the selector switch selector switch selector switch selector switch according to the applications according to the applications according to the application...

Page 14: ...r main burner flames causing fire or explosion Some local codes permit operation of gas appliances if installed 18 inches or more above the floor This may reduce the risk if location in such an area c...

Page 15: ...ttach field piping to unit The heating pipe should be 3 4 and of type L copper or PEX Never use aluminum plastic or galvanized steel piping The pipe size used for supply supply supply supply heating w...

Page 16: ...speciality plumbing supplier M M M Mixing ixing ixing ixing type valve type valve type valve type valve Controls the desired hot water temperature and ensures constant hot water temperature in the fau...

Page 17: ...curves The flue should have a diameter larger than that of the flue of the boiler Do not place flammable items near the boiler Never place combustibles such as vinyl bags matches thinner etc on boile...

Page 18: ...xplosion Some local codes permit operation of gas appliances if installed 18 inches or more above the floor This may reduce the risk if location in such an area cannot be avoided Flammable items press...

Page 19: ...called drip leg must be incorporated in the piping The dirt leg must be readily accessible and not subject to freezing conditions Install in accordance with recommendations of gas supplier Refer to na...

Page 20: ...ity fill The pump will run continuously and the low water level sensor will be automatically turned on off for 1 minute intervals Ensure that all water valves to unit are open Twist open approx 1 2 tu...

Page 21: ...d Due to the extremely low flue temperatures the QVM 9 Series boiler may be vented using 3 schedule 40 venting materials Cut all lengths of pipe cleanly maintaining a 90 degree square edge Use long ra...

Page 22: ...leaks Do not use any aluminum duct as an extension Use extension duct sets or elbows available through your Quietside distributor The flue duct which carries combustion waste gas should be firmly sec...

Page 23: ...flue ensuring that it cannot be blocked by snow falling from the eaves Install the flue in a location where no opening exists within 20 from the flue so that exhaust gas cannot recirculate into the bu...

Page 24: ...ed IMPORTANT The siphon reservoir in the boiler should be filled with water If no water is available do not operate the boiler The condensed water should not be used for drinking water Be sure to clea...

Page 25: ...ould find that setting the thermostat to the water temperature sensing function will provide the best comfort We suggest trying them both The Air Temperature Mode The Air Temperature Mode The Air Temp...

Page 26: ...n Installation Installation Installation 1 Remove the back plate from the FR 5 thermostat by grasping the faceplate with one hand and sliding the back plate downward with the other hand 2 Pull the the...

Page 27: ...emperature Button and Room Temperature Button and Lamp green Lamp green Lamp green Lamp green The unit runs according to the room temp set by the room temperature button and the lamp indicates that th...

Page 28: ...om temperature e g Winter Season Fcl Cast Spring Fall Season Base Fcl 4 To stop the operation in this mode set the temperature control below 104 Rad The unit will stop but the freeze prevention functi...

Page 29: ...erating in this mode 1 Press the Set Temperature button The room temperature will be indicated on the temperature display and the Room Temperature lamp and ON light will go on 2 Turn the Set Temperatu...

Page 30: ...rvice The two wires at the back of the room thermostat may be connected together for emergencies A specific heating water temperature will be automatically set and the unit will start To stop the unit...

Page 31: ...t your heating dealer or a qualified technician with the gas utility company Test for leakage at all gas piping connections AC 115 volts 15 Amp dedicated circuit with approved grounded connection Heat...

Page 32: ...source is AC 115V 60Hz STEP 5 STEP 5 STEP 5 STEP 5 Turn 1 DIP switch to ON position Trial Operation mode STEP 6 STEP 6 STEP 6 STEP 6 Install the room thermostat FR 5 Power lamp will flash 1 second ON...

Page 33: ...vent in order to bleed air from the unit Shut off the manual air vent when the pressure in the heating piping reaches the operating pressure The automatic air vent will automatically remove remaining...

Page 34: ...Check Lamp is lit note the error code shown to assist in repair and service of the boiler If the boiler exterior is dirty disconnect power to the boiler wipe the boiler with a wet cloth soaked with mi...

Page 35: ...he unit and immediately contact the installer or service company 5 5 5 5 Check for lack of heating water Low volume or flow of water supplied to tub or faucets Check the pressure of the incoming water...

Page 36: ...te heat exchanger being careful not to cause stress to other fittings and connections Check O ring on tube ends and replace if necessary CLEANING CLEANING CLEANING CLEANING In some applications the fl...

Page 37: ...iltering impurities from the system When heating performance is decreased clean the filter by removing clip washing out and re inserting the filter Replace the clip THE WATER FLOWING OUT OF THE PRESSU...

Page 38: ...Heating Sensor Short Circuit Non applicable 07 Hot Water Sensor Wire Disconnected Non applicable 08 Hot Water Sensor Short Circuit Sensor failure Check voltage Pin 19 8 on 21Pin connector main contro...

Page 39: ...failure 12 12 12 12 Flam e failure in com bustion 04 04 04 04 Pseudo flam e 13 13 13 13 Heating water S W failure Closed Air Type 05 05 05 05 Breakage of heating sensor 14 14 14 14 Gas alarm 06 06 06...

Page 40: ...FOR FLAME DETECTOR GRY GRAY EV 2 EV 1 THREE WAY VALVE 1 BLK RED HOT WATER 2 BLK BLU HEATING WATER BLU BLU IGNITION TRANS AC115V 60Hz AC 115V 60Hz GRN EARTH 2 8 7 1 13 PIN 9 3 10 12 11 5 4 13 6 5 7 6 8...

Page 41: ...Notapwatersupply Fill theheatingwater Contact theservicecenter The unit does notwork 01 isindicatedonthe temperature indicator Clogged heatingpipe Circulation pumpfailure Checkforanycloggingintheheat...

Page 42: ...loded Views Exploded Views 3 4 5 2 6 7 8 9 10 31 32 11 12 44 18 19 14 13 15 16 17 20 21 22 23 62 34 26 27 28 29 41 63 30 35 33 36 37 39 38 45 43 46 54 42 40 52 49 53 50 59 Room Thermostat Model FR 5 1...

Reviews: