Routine Maintenance
Routine Maintenance
Routine Maintenance
Routine Maintenance
■
For failure-free, safe and economical use, routinely check and clean the gas boiler.
■
Checks and maintenance should be done after the gas valve has been closed and the boiler has
cooled down fully.
■
Other matters not specifically covered in the following checks and maintenance refer to the
trained technician.
■
Apply soapy water on the gas piping, shutoff valve and
the gas connections to check for leaks.
■
Check for any rust and clogs in the flue duct.
■
Check if the
“
Check Lamp
”
is
“
ON
”
(FR-5 thermostat).
■
If
“
Check Lamp
”
is lit, note the error code shown to
assist in repair and service of the boiler.
■
If the boiler exterior is dirty, disconnect power to the
boiler, wipe the boiler with a wet cloth soaked with mild
detergent and remove moisture with dry cloth.
Call a
Call a
Call a
Call a Quietside
Quietside
Quietside
Quietside Coporation
Coporation
Coporation
Coporation
authorized service
authorized service
authorized service
authorized service
technician
technician
technician
technician
DO NOT USE A NYLON BRUSH OR OTHER STATIC
CREATING MATERIAL TO CLEAN DUST AND CARBON
DEPOSITS FROM HEATING SURFACES AND VENT.
SUCH DEPOSITS ARE FLAMMABLE AND MAY BE
IGNITED BY STATIC ELECTRICITY. USE A METAL
BRUSH TO MINIMIZE THE DANGER OF EXPLOSION.
DO NOT ATTEMPT TO SERVICE YOUR APPLIANCE
YOURSELF.
Maintenance and Cleaning
Maintenance and Cleaning
Maintenance and Cleaning
Maintenance and Cleaning
Routine Checks
Routine Checks
Routine Checks
Routine Checks
FR-5
Room
Thermostat