POT 1, POT 2 AND POT 3 ADJUSTMENT
RADAR card is equipped with 3 potentiometers, to adjust its operation scheme. Functions of these
potentiometers are as outlined below:
FUNCTION
POT 1
With this potentiometer you can set the maximum speed of the motion you want to
detect. Rotating POT 1 clockwise (+), maximum speed RADAR will sense motion is
increased. Rotating POT 1 counterclockwise ayarını (), maximum speed sensed
is reduced.
POT 2
With this potentiometer you can set the power of RADAR. Clockwise rotation (+) of POT
2 boosts the operating power hence the detection range. Counterclockwise rotation (-)
reduces the operating power hence the detection range.
POT 3
With this potentiometer you can set the sensitivity of RADAR. Rotating POT 3 clockwise
(+) the sensitivity is reduced while counterclockwise (-) rotation increases the sensitivity.
NC CONTACT APPLICATION
POT 1
POT 2 POT 3
POT 1
3
2
1
JMP 1
3
2
1
JMP 1
GREEN
GREEN
BROWN
BROWN
WHITE
WHITE
YELLOW
YELLOW
POT 2 POT 3
O
F
F
JU
M
P
E
R
O
N
O
F
F
JU
M
P
E
R
O
N
NO CONTACT APPLICATION
NC CONTACT APPLICATION