Section V - Operating Instructions

Flow & Purity Controller Operation

The Flow & Purity Controller maintains the 

nitrogen purity by varying the flow out of 

the system while under constant pressure 

changes.

Flow & Purity Control Operation 

procedure

The Flow & Purity Controller is factory set 

to the user’s requirement and should not be 

changed unless the compressed air going 

into the generator varies more than 10 psig 

from the air pressure specified at time of 

order, or the air pressure was unknown at 

time of order.

 NOTICE!

If  the  purity  is  not  at  or  better 

than required and the pressure and 

temperature  going  into  the  system 

are  as  required,  the  Flow  &  Purity 

Controller  can  be  adjusted  to  meet 

the  purity  demand.  Adjusting  the 

Controller will directly affect the flow 

of nitrogen out of the system. To get 

better purity, flow must decrease.  A 

lower purity will increase flow.  

The controller has a 3/32” hex screw on the 

opposite side of the inlet port. Clockwise 

will decrease flow, counterclockwise will 

increase flow. If an analyzer is installed, 

make gradual adjustments, allowing 120 

seconds between adjustments to allow for 

flow change and the analyzer to settle. 

12 

Quincy Compressor-DEFENDER™

Summary of Contents for DEFENDER 7-2716 SCFH

Page 1: ...tant safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting to operate or perform maintenance on this eq...

Page 2: ......

Page 3: ...densate Drain Connections 8 Nitrogen Piping Connections 8 Compressed Air Inlet Connection 8 Pre start Inspection 9 Initial Start up Adjustment 9 Nitrogen Purity Sampling Setup 9 Section V Operating In...

Page 4: ......

Page 5: ...in minor personal injury or property damage NOTICE Identifies important installation operation or maintenance information which is not hazard related DANGER This symbol identifies immediate hazards w...

Page 6: ...s manual before attempting to operate the unit Although this unit is very simple to operate the user will be working with high pressure gas that must be handled with caution DANGER Compressed gas if h...

Page 7: ...o not substantially fulfill performance requirements set forth in the Company literature and are manufactured in accordance with the Company s s p e c i f i c a t i o n s o r g o v e r n m e n t speci...

Page 8: ...arbon carryover at or below 2 parts per billion Nitrogen System Description Inside the DEFENDER nitrogen generator the compressed air rst comes into contact with the membrane pre ltration system On St...

Page 9: ...he analyzer Two pressure gauges are installed on the front panel One is for displaying inlet pressure and the other for system outlet pressure Example of a QUINCY DEFENDER FILTER 3 ACTIVATED CARBON FI...

Page 10: ...depleted levels of oxygen is given below Effects Symptoms of Decreased oxygen Levels 15 19 Decreased ability to work s t r e n u o u s l y M a y i m p a i r coordination and may induce early symptoms...

Page 11: ...he presence of oxygen rich air It is imperative that vented gas be discharged only in safe well ventilated areas If the unit is located in a poorly ventilated room the waste gas must be piped to a ven...

Page 12: ...il and particle removing ltration is included in the nitrogen generator so pre ltration is not required Condensate Drain Connections A bulkhead connection is provided on the bottom of the panel to con...

Page 13: ...re pressurize after each purge The nitrogen can be delivered to the system after the initial purging procedure Nitrogen Purity Sampling Setup 1 If the unit is equipped with the built in analyzer make...

Page 14: ...t isolation valve and perform the purge process again If the tank remains pressurized during downtime weekends holidays etc this step is not required 3 Go Online After venting the system is ready to u...

Page 15: ...ver adjusting the Pilot Valve use small increments and keep the differential at 15 20 psig NOTICE During the adjustment process the valve may begin opening and closing rapidly this happens when the di...

Page 16: ...wn at time of order NOTICE If the purity is not at or better than required and the pressure and temperature going into the system are as required the Flow Purity Controller can be adjusted to meet the...

Page 17: ...Stuff clean rag into lter bowl to keep unit clean while changing the elements 2 Unscrew the locking nut on the bottom of the element and discard the element Replace the element with a new one of the...

Page 18: ...rom the top end of the carbon vessel to allow access to the carbon Drain the carbon into a container and replace with fresh carbon d Replace Hex bushing with screen attached using Te on tape on the th...

Page 19: ...PERATION OF ALL SAFETY RELIEF VALVES ANNUALLY OR AT 8000 HOURS REPLACE ALL FILTER ELEMENTS ON THE UNIT CHANGE THE CARBON IN THE CARBON BED ANALYZER S SENSOR WILL NEED REPLACING EVERY 2 3 YEARS NOTICE...

Page 20: ...1 CXNT 00030 COALESCING PRE FILTER NO 2 COMPLETE 1 ACNT 00030 ADSORBING PRE FILTER NO 3 COMPLETE DEFENDER N2GEN 270 520 PREMIUM FILTRATION QTY PART DESCRIPTION 1 CSNE 00030 COALESCING PRE FILTER ELEME...

Page 21: ...PRE FILTER NO 1 COMPLETE 1 CXNT 00060 COALESCING PRE FILTER NO 2 COMPLETE 1 ACNT 00060 ADSORBING PRE FILTER NO 3 COMPLETE DEFENDER N2GEN 1800 PREMIUM FILTRATION QTY PART DESCRIPTION 1 CSNE 00150 COALE...

Page 22: ...isk and storage charges may be applied at the discretion of Seller Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law such interest sh...

Page 23: ...d to seller freight prepaid for inspection Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship under normal use and service for ninety 90 day...

Page 24: ..._____________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ________...

Page 25: ......

Page 26: ...te Alabama 36507 Phone 251 937 5900 Fax 251 937 1457 Nearest Distributor 888 424 7729 E mail info quincycompressor com The Science of Compressed Air quincycompressor com 2005 Quincy Compressor an EnPr...

Reviews: