Technical Data
Technical Data
T
ECHNICAL
D
ATA
EWS 20
EWS 100
C
ONTAINER
C
APACITY
(
GALLONS
)
2.6
17.7
F
ILLING
V
OLUME
(
GALLONS
)
1.1
12.4
C
ONDENSATE
F
EED
(
HOSE
)
½"
½"/1"*
W
ATER
O
UTLET
(
HOSE
)
½"
1"
W
EIGHT
E
MPTY
9 lbs.
24.6
M
INIMUM
/M
AXIMUM
T
EMPERATURE
34/140°F
34/140°F
M
AXIMUM
O
PERATING
P
RESSURE
OF
C
OMPRESSED
AIR
S
YSTEM
230
PSIG
230
PSIG
* Connection of flow splitter (see page 8).
Design Parameters
Lubricant characteristics:
Carryover:
6 ppm of compressed air at 110 psi
Type: Turbine oil without additives
EWS 20
EWS 100
C
OMPRESSOR
C
APACITY
20
HP
100
HP
C
OMPRESSOR
U
SAGE
F
ACTOR
100 %
100 %
Cartridge life 1000 hours
Note: Characteristics of compressor condensate
depend on several factors, such as:
• Type of lubricant
• Type and number of additives
• Heat of compression
• Composition of ambient air
The variety of combinations of these and other
factors, such as lubricant carryover, age of
lubricant, and compressor usage factor will have
a great effect on the actual filter life.
Connecting the EWS in parallel will multiply the
performance by the number of units. However,
differences in filter performance may be noted,
caused by uneven flow from the flow splitter,
due to manufacturing tolerances, and off-level
mounting.
It is recommended that the filter be changed
every six months, or less.
16
Quincy Compressor-EWS Emulsion Separator