Instruction Book
9828 0934 73
123
QPVS-650 (
ES 310 VSD
)
–
QPVS-850 (
ES 410 VSD
)
–
QPVS-1050 (
ES 510 VSD
)
Air-cooled 50 Hz
Performance data
Unit
QPVS650
QPVS850
QPVS1050
Pressure dewpoint air outlet
Economy mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
5
5
5
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
41
41
41
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
20
20
20
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
68
68
68
Maximum saving mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
10
10
10
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
50
50
50
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
25
25
25
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
77.0
77.0
77.0
Lowest dewpoint mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
°C
3
3
3
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
°F
37.4
37.4
37.4
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
°C
17
17
20
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
°F
62.6
62.6
68
Total electrical power input
Economy mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
kW
2.06
2.76
3.3
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
hp
2.76
3.70
4.43
•
Ambient air temperature 40 °C
Compressed air inlet temperature 50 °C
kW
4.12
4.98
6.6
•
Ambient air temperature 104 °F
Compressed air inlet temperature 122 °F
hp
5.53
6.68
8.85
Maximum saving mode
•
Ambient air temperature 25 °C
Compressed air inlet temperature 35 °C
kW
1.6
1.94
2.54
•
Ambient air temperature 77 °F
Compressed air inlet temperature 95 °F
hp
2.15
2.60
3.41