UL/cUL approval
Compressor type
I (1)
Max. fuse (1)
I (2)
Max. fuse (2)
K5/
HRC form II
K5/
HRC form II
V
Hz
A
A
A
A
QGD 50
230
60
352.2
400
362.6
400
QGD 50
380
50
218.8
250
222.9
250
QGD 50
380
60
221.4
250
226.2
250
QGD 50
460
60
182.4
200
188.8
225
QGD 50
575
60
145.9
160
151.6
175
UL/cUL approval
Compressor type
I (1)
Max. fuse (1)
I (2)
Max. fuse (2)
K5/
HRC form II
K5/
HRC form II
V
Hz
A
A
A
A
QGD 60
230
60
440.8
500
451.2
500
QGD 60
380
50
260.8
300
264.9
300
QGD 60
380
60
267.5
300
272.3
300
QGD 60
460
60
222.2
250
228.6
250
QGD 60
575
60
176.6
200
182.3
200
I: current in the supply lines at maximum load and nominal voltage
(1): compressors without integrated dryer
(2): compressors with integrated dryer
Fuse calculations for cUL and UL
: The indicated fuse size is the maximum fuse size in order to
protect the motor against short circuit. For cUL fuse HRC form II, for UL fuse class RK5.
Possible configurations
There are 3 possible cabling layouts:
• (1): Single supply cables.
• (2): Parallel supply cables
Instruction book
2920 7190 02
99
Summary of Contents for QGD 40
Page 1: ...Quincy Oil injected rotary screw compressors QGD 40 QGD 50 QGD 60 Instruction book...
Page 2: ......
Page 14: ...Front view compressors with integrated dryer Instruction book 12 2920 7190 02...
Page 15: ...Front view open compressors without dryer Instruction book 2920 7190 02 13...
Page 16: ...Rear view compressors without dryer Instruction book 14 2920 7190 02...
Page 17: ...Front view open compressors with integrated dryer Instruction book 2920 7190 02 15...
Page 112: ......
Page 113: ......