Flow diagram, air circuit (compressors with integrated dryer)
Reference
Description
1
Intake air
2
Air/oil mixture
3
Oil
4
Wet compressed air
5
Condensate
6
Dried compressed air
Description
Air drawn through inlet filter (AF) and open inlet valve (IV) of the unloader is compressed in
compressor element (E). A mixture of compressed air and oil flows into the air receiver/oil
separator tank (AR). The air is discharged through outlet valve (AV) via minimum pressure valve
(Vp) and air cooler (Ca).
The air cooler is provided with a moisture trap (MT).
On compressors with integrated dryer, the air flows through air dryer (DR) before it is discharged
through outlet valve (AV). Also see section
Instruction book