3.19 Programmable settings
Parameters: unloading/loading pressures
Minimum
setting
Factory
setting
Maximum
setting
Unloading/loading pressures
see
see
see
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor element outlet temperature
(shut-down warning level)
˚C
50
113
119
˚F
122
235
246
Compressor element outlet temperature
(shut-down level)
˚C
111
120
120
˚F
232
248
248
Service plan
The built-in service timer will give a Service warning message after a preprogrammed time
interval has elapsed.
Also see section
Preventive maintenance schedule
.
Consult your supplier if a timer setting has to be changed. The intervals must not exceed the
nominal intervals and must coincide logically.
Terminology
Term
Explanation
ARAVF
Automatic restart after voltage failure.
Power recovery
time
Is the period within which the voltage must be restored to have an automatic restart. Is
accessible if the automatic restart is activated. To activate the automatic restart function,
consult your supplier.
Restart delay
This parameter allows to programme that not all compressors are restarted at the same
time after a power failure (ARAVF active).
Instruction book
2920 7190 02
63
Summary of Contents for QGD 40
Page 1: ...Quincy Oil injected rotary screw compressors QGD 40 QGD 50 QGD 60 Instruction book...
Page 2: ......
Page 14: ...Front view compressors with integrated dryer Instruction book 12 2920 7190 02...
Page 15: ...Front view open compressors without dryer Instruction book 2920 7190 02 13...
Page 16: ...Rear view compressors without dryer Instruction book 14 2920 7190 02...
Page 17: ...Front view open compressors with integrated dryer Instruction book 2920 7190 02 15...
Page 112: ......
Page 113: ......