5.5
Checking the display
5.6
Stopping
Airlogic² control panel
Procedure
Step
Action
1
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after
30 seconds of unloaded operation.
2
To stop the compressor in the event of an emergency
, press emergency stop button (10).
Alarm LED flashes (7).
Do not use emergency stop button for normal stopping!
3
Close the air outlet valve.
4
Press the test button on top of the electronic water drain(s) (if supplied) to the depressurize the
piping between air receiver and outlet valve, next open the manual drain valve (Dm). See
section
.
Switch off the voltage.
5.7
Taking out of operation
Warning
The operator must apply all relevant
.
Instruction book
2920 7190 02
81