Oil filler plug
This procedure should be carried out at the end of the compressor’s service life.
Step
Action
1
Stop the compressor and close the air outlet valve .
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurise the compressor by opening plug (3) one turn.
Open condensate drain valve (4) of the air receiver.
4
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor from the air net.
5
Drain the oil and condensate circuits.
6
Disconnect the compressor condensate outlet and valve from the condensate net.
Instruction book
60
2920 7113 40
Summary of Contents for QGS 10
Page 1: ...Quincy Oil injected rotary screw compressors QGS 10 QGS 15 QGS 20S Instruction book ...
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7113 40 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7113 40 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7113 40 49 ...
Page 68: ...The new service interval is now set Instruction book 66 2920 7113 40 ...
Page 74: ...Line filters Instruction book 72 2920 7113 40 ...
Page 84: ...8 Problem solving Control panel Air outlet valve Instruction book 82 2920 7113 40 ...
Page 85: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7113 40 83 ...
Page 94: ......
Page 95: ......