9.3
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
bar(e)
Working pressure
psi
Limitations
Maximum working pressure
bar(e)
Maximum working pressure
psig
Minimum working pressure
bar(e)
4
Minimum working pressure
psig
58
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
9.4
Compressor data
Compressor type
7.5kW /
10HP
11kW /
15HP
15kW /
20HP
Frequency
Hz
60
60
60
60
Maximum (unloading) pressure UL units
bar
7.4
9.1
10.8
12.5
Maximum (unloading) pressure UL units
psig
107
132
157
182
Nominal working pressure
bar
6.9
8.6
10.3
12.1
Nominal working pressure
psig
100
125
150
175
Set-point, thermostatic valve
˚C
71
71
71
71
Set-point, thermostatic valve
˚F
160
160
160
160
7.5kW / 10HP
7.5kW / 10HP
Temperature of air leaving outlet valve (a)
approx., tank mounted units.
˚C
7
˚F
45
Instruction book
2920 7113 40
87
Summary of Contents for QGS 10
Page 1: ...Quincy Oil injected rotary screw compressors QGS 10 QGS 15 QGS 20S Instruction book ...
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7113 40 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7113 40 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7113 40 49 ...
Page 68: ...The new service interval is now set Instruction book 66 2920 7113 40 ...
Page 74: ...Line filters Instruction book 72 2920 7113 40 ...
Page 84: ...8 Problem solving Control panel Air outlet valve Instruction book 82 2920 7113 40 ...
Page 85: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7113 40 83 ...
Page 94: ......
Page 95: ......