10
Instructions for use
Oil separator vessel
1
The vessel can contain pressurised air. This can be potentially dangerous if the
equipment is misused.
2
This vessel must only be used as a compressed air/oil separator tank and must be
operated within the limits specified on the data plate.
3
No alterations must be made to this vessel by welding, drilling or other mechanical
methods without the written permission of the manufacturer.
4
The pressure and temperature of this vessel must be clearly indicated.
5
The safety valve must correspond with pressure surges of 1.1 times the maximum
allowable operating pressure. It should guarantee that the pressure will not permanently
exceed the maximum allowable operating pressure of the vessel.
6
Use only oil as specified by the manufacturer.
Air receiver (on tank-mounted units)
1
Corrosion must be prevented: depending on the conditions of use, condensate
may accumulate inside the tank and must be drained every day.
This may be done
manually by opening the drain valve, or by means of the automatic drain, if fitted to the
tank. Nevertheless, a weekly check of correct functioning of the automatic valve is
needed. This has to be done by opening the manual drain valve and check for
condensate. Verify that no rust obstructions affect the drain system.
2
Yearly service inspection of the air receiver is needed, as internal corrosion can
reduce the steel wall thickness with the consequent risk of bursting
. Local rules
need to be respected, if applicable. The use of the air receiver is forbidden once the wall
thickness reaches the minimum value as indicated in the service manual of the air
receiver (part of the documentation delivered with the unit).
3
Lifetime of the air receiver mainly depends on the working environment. Installing the
compressor in a dirty and corrosive environment is not allowed, as this can reduce the
vessel lifetime dramatically.
4
Do not anchor the vessel or attached components directly to the ground or fixed
structures. Fit the pressure vessel with vibration dampers to avoid possible fatigue
failure caused by vibration of the vessel during use.
5
Use the vessel within the pressure and temperature limits stated on the nameplate and
the testing report.
6
No alterations must be made to this vessel by welding, drilling or other mechanical
methods.
Instruction book
90
2920 7113 40
Summary of Contents for QGS 10
Page 1: ...Quincy Oil injected rotary screw compressors QGS 10 QGS 15 QGS 20S Instruction book ...
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7113 40 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7113 40 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7113 40 49 ...
Page 68: ...The new service interval is now set Instruction book 66 2920 7113 40 ...
Page 74: ...Line filters Instruction book 72 2920 7113 40 ...
Page 84: ...8 Problem solving Control panel Air outlet valve Instruction book 82 2920 7113 40 ...
Page 85: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7113 40 83 ...
Page 94: ......
Page 95: ......