It remains possible to check the actual status of other parameters by pressing the enter button (7)
for 3 seconds. Press button (3) to stop the compressor and wait until the compressor has
stopped. The warning message will disappear as soon as the warning condition disappears.
3.7
Shutdown
Description
The compressor will stop:
• In case the temperature at the outlet of the compressor element exceeds the shutdown level
(detected by temperature sensor (TT11) or by temperature switch (TSHH11)).
• In case of error of the outlet pressure sensor (PT20) or temperature sensor (TT11).
• In case of overload of the compressor motor (M1)
Compressor element outlet temperature
If the outlet temperature of the compressor element exceeds the shutdown level (factory setting
115˚C/239˚F):
• The compressor will stop.
• Alarm LED (5) will flash.
• The following screen will appear:
Instruction book
32
2920 7113 40
Summary of Contents for QGS 10
Page 1: ...Quincy Oil injected rotary screw compressors QGS 10 QGS 15 QGS 20S Instruction book ...
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7113 40 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7113 40 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7113 40 49 ...
Page 68: ...The new service interval is now set Instruction book 66 2920 7113 40 ...
Page 74: ...Line filters Instruction book 72 2920 7113 40 ...
Page 84: ...8 Problem solving Control panel Air outlet valve Instruction book 82 2920 7113 40 ...
Page 85: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7113 40 83 ...
Page 94: ......
Page 95: ......