• Install 80 A fuses on each cable.
The indicated fuse size is the maximum fuse size in order to protect the motor against short circuit. For cUL
fuse HRC form II, for UL fuse class RK5.
9.2
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Limits
Maximum working pressure
Minimum working pressure
bar(e)
4
Minimum working pressure
psig
58
Maximum air inlet temperature
˚C
46
Maximum air inlet temperature
˚F
115
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
9.3
Compressor data
Reference conditions
All data specified below apply under reference conditions, see section
Gearbox driven units
Units
7.5 bar
8 bar
10 bar
13 bar 100 psi 125 psi 150 psi 175 psi
Frequency
Hz
50
50
50
50
60
60
60
60
Nominal working
pressure
bar(e) 7
8
9.5
12.5
6.9
8.6
10.3
12
psig
102
116
138
181
100
125
150
175
Maximum working
pressure
bar(e) 7.5
8
10
13
7.4
9.1
10.8
12.5
psig
109
116
145
189
107
132
157
181
Unloading pressure
Factory setting
bar(e) 7
8
9.5
12.5
6.9
8.6
10.3
12
psig
102
116
138
181
100
125
150
175
Instruction book
88
2920 7101 21