Instruction book
2012 2039 28
102
Motor direction arrow
Check the direction of rotation (a sticker is provided on the motor non-drive side indicting the rotation
direction). Press the "Start" button, followed immediately by the emergency stop button.
If it does not spin in the right direction reverse two mains cables. When it rotates in the correct direction, the
fluid level should drop after 4 or 5 seconds of operation.
Incorrect rotation of the drive motor can cause damage to the compressor.
5.2 Before starting
Remarks
If the compressor has not run for the past 6 months, it is strongly recommended to
improve the lubrication of the airend (AE) at starting. Disconnect the inlet hose,
remove the unloader (UA) and pour 0.75 l (0.20 US gal, 0.17 Imp gal) of fluid into the
airend (AE). Reinstall the unloader and reconnect the inlet hose. Make sure that all
connections are tight.
Procedure
-
Check the luid level, top up if necessary. See section