m) PHYSICAL PROPERTIES RESULTS - Particle size is measured in microns.
Refer the “Appendix 2: Fluid
Parameters”.
n) SPECTROCHEMICAL ANALYSIS -
Refer the “Appendix 2: Fluid Parameters”.
7.9 Fluid Sampling Procedure
Preferred sample location is the fluid filter. If unable to take sample from fluid filter procedure as follow:
1. Shutdown and lockout compressor.
2. Relieve pressure in reservoir.
3. Remove plug from reservoir drain line.
4. Drain water from reservoir and discard in approved manner.
5. Fill sample bottle with fluid.
6. Close valve and replace plug in drain line.
7. Return compressor to the service and check fluid level during operation. Service fluid as required.
Using fluid filter sample valve, proceed as follow:
1. Open valve, drain 2-4 Ounce of fluid from filter and discard in the approved manner.
2. Fill sample bottle.
3. Close valve.
After collecting sample from other the above method:
1. Fill out information label completely.
Be certain to provide all information as to possible hazards related to a given sample.
If hazards exist, the information must be clearly marked on the sample bottle label.
2. Attached sample bottle label and put bottle in Mailer.
3. Please shipping label on the outside of the Mailer and send it by UPS.
Sample Battle Label
Shipping label
A fluid sample valve kit is available from Quincy compressor. Contact the service
department ask for part number 2011020140.