4.2 Installation proposal
Receiving
Upon receipt, immediately inspect the compressor for any visible damage that may
have occurred during shipment. If visible damage is found, the delivering carrier should
make a notation on the freight bill and the customer should request a damage report. If
the shipment is accepted and damage is found later, it is classified as concealed
damage.
Concealed damage should be reported to the delivering carrier within 15 days of
delivery. The delivering carrier must prepare a damage report. Itemized supporting
papers are essential to filing a claim. Read the compressor nameplate to be sure the
compressor is the model and size ordered and that optionally ordered items are
included.
Check the reservoir and pressure relief valves to be sure they are adequate for the
pressure at which you intend to operate.
Outdoor/altitude operation
The compressor is not designed for installation outdoors.
Also, if the ambient temperature can fall down be
low 0 ˚C (32 ˚F), and if operating
above 1000 m (3300 ft) precautions must be taken. In this case, consult your supplier.
Moving/lifting
The compressor can be moved by a lift truck using the slots in the frame. Take care
not to damage the bodywork during lifting or transport. Make sure that the forks
protrude from the other side of the frame.
The compressor can also be lifted after inserting beams in the slots. Make sure that
the beams cannot slide and that they protrude from the frame equally.
The chains must be held parallel to the bodywork by chain spreaders in order not to
damage the compressor. The lifting equipment must be placed in such a way that the
compressor is lifted perpendicularly. Lift gently and avoid twisting.
Important Requirements for New Installation
To insure a safe installation of the equipment it is important to make sure final inspection checks of the
equipment are made before running for the first time.
With all electrical power removed from the equipment and per OSHA requirements for lock-out and tag-
out you can safely make the following inspection checks.
The electrical installation must be done by qualified personnel.
Inspect all electrical connections to verify there are no loose connections and all electrical connections
are tight.
Verify that the power requirement for the package has been provided for by referencing the package
power label on the inside of the electrical cabinet door on the package.
The branch circuit protection and supply cable size for the compressor must be sized to meet the
package power requirement per local electrical codes. Also verify that the package is correctly grounded
using the proper size wire connected to a tested earth ground. An improper electrical installation can
result in damage to or failure of the equipment. This could also result in a fire and fatalities.
The piping installation must be done by qualified personnel. Inspect all piping sizes and pressure ratings
to insure the proper pipe has been used for the compressor package being installed.