Section IX - Technical data
98
Quincy Compressor
Compressor data
Notice!
All data specified below apply under reference conditions, see section Reference
conditions and limitations.
8 bar compressors, 50 Hz
Compressor type
QOF 20
QOF 22
QOF 30
Maximum working pressure (compressors
without integrated dryer)
bar(e)
8
8
8
Maximum working pressure (compressors
without integrated dryer)
psi(g)
116
116
116
Maximum working pressure (compressors with
integrated dryer)
bar(e)
7.75
7.75
7.75
Maximum working pressure (compressors with
integrated dryer)
psi(g)
112
112
112
Reference working pressure (compressors
without integrated dryer)
bar(e)
7
7
7
Reference working pressure (compressors
without integrated dryer)
psi(g)
101.5
101.5
101.5
Reference working pressure (compressors with
integrated dryer)
bar(e)
6.75
6.75
6.75
Reference working pressure (compressors with
integrated dryer)
psi(g)
98
98
98
Air temperature at outlet valve (compressors
without integrated dryer)
°C
32
30
30
Air temperature at outlet valve (compressors
without integrated dryer)
°F
90
86
86
Air temperature at outlet valve (compressors
with integrated dryer)
°C
25
25
20
Air temperature at outlet valve (compressors
with integrated dryer)
°F
77
77
68
Motor shaft speed
rpm
2900
2900
2900
Nominal motor power
kW
4 x 3.7
3 x 5.5
4 x 5.5
Nominal motor power
hp
4 x 5
3 x 7.5
4 x 7.5
Sound pressure level (compressors without
integrated dryer)
dB(A)
63
64
65
Refrigerant type (compressors with integrated
dryer)
°C
R404a
R404a
R404a
Dew point (compressors with integrated dryer)
°F
4
4
4
Dew point (compressors with integrated dryer)
°F
39
39
39