Section IX - Technical data
Quincy Compressor
101
Compressor type
QOF 20
QOF 22
QOF 30
Reference working pressure (compressors with
integrated dryer)
psi(g)
127
127
127
Air temperature at outlet valve (compressors
without integrated dryer)
°C
32
30
30
Air temperature at outlet valve (compressors
without integrated dryer)
°F
90
86
86
Air temperature at outlet valve (compressors
with integrated dryer)
°C
25
30
55
Air temperature at outlet valve (compressors
with integrated dryer)
°F
77
86
131
Motor shaft speed
rpm
3505
3505
3505
Nominal motor power
kW
4 x 3.7
3 x 5.5
4 x 5.5
Nominal motor power
hp
4 x 5
3 x 7.5
4 x 7.5
Sound pressure level (compressors without
integrated dryer)
dB(A)
63
64
65
Refrigerant type (compressors with integrated
dryer)
R404a
R404a
R404a
Dew point (compressors with integrated dryer)
°C
4
4
4
Dew point (compressors with integrated dryer)
°F
39
39
39