Section IV - Installation guidelines
Quincy Compressor
73
Installation proposal
Reference
Description
1
Minimum free area to be reserved for the compressor installation
2
Ventilation proposals
Procedure
1. Install the compressor on a level floor, suitable for taking the weight of the
compressor in a frost free and preferably low dust location.
2. Compressed air outlet valve.
3. Delivery pipe.
The pressure drop over the air delivery pipe can be calculated as follows:
Δ
p = (L x 450 x Qc
1.85
) / (d
5
x P), with
d = inner diameter of the pipe in mm