Section VII - Adjustments and servicing procedures
86
Quincy Compressor
Procedure:
1. Stop the compressor and switch off the power.
2. Close the air outlet valve and depressurise the compressor.
3. Remove the fan duct:
• Unscrew the 3 bolts (1).
• Remove clip (2) (if applicable).
• Remove fan duct (3).
4. Clean cooling channels:
• Remove dust from the cooling channels (1) by means of air jet (see next figure).
• Clean the fan duct (2).
5. Reassemble the fan duct:
• Put the fan duct in place.
• Fit the 3 bolts and the clip.
The unit is now again ready for use.