QR-25 Series
Quincy Compressor
52201-107, December 2012
13
3501 Wismann Lane, Quincy IL - 62305-3116
Single Phase Magnetic Motor Starter
W
ith
Automatic Start / Stop Control
W
iring Schematic
WP1744B
Magnetic Starter
Contactor
Overload
Relay
Connect incoming power lines
at screw terminals L1 & L2.
CA
UTION !
V
erify all wires are secure and fasteners are torqued before connecting power to
the unit.
All wires are red unless otherwise specified.
Dashed lines represent wires supplied by others.
At Installation, the customer is to provide:
Disconnect and branch circuit overcurrent protection and grounding between the power supply and the electrical control enclosure in accor
-
dance with the National Electrical Code (NEC), the Canadian Electrical Code (CEC) and / or any local codes having precedence.
Summary of Contents for QR-25 210
Page 42: ......