Section VII - Compressor Fluids
42
Quincy Compressor
®
- QSB/T
™
QuinSyn Plus
Effective on orders entered on December 1, 2000 and
later, Quincy Compressor
®
began offering QuinSyn
Plus, an extended life synthetic fluid.
QuinSyn Plus is
an optional factory fill for Quincy rotary screw
compressors. Machines ordered with QuinSyn Plus as the
factory fill will be eligible for a five-year extended airend
warranty.
QuinSyn Plus is an ISO 46 viscosity fluid with an 8,000
hour life under normal operating conditions (exact fluid
life is determined by the fluid analysis program). It is a
synthetic hydrocarbon/ester fluid.
QuinSyn Plus is totally compatible with QuinSyn.
Machines currently running with QuinSyn fluid can be
topped off with QuinSyn Plus with no adverse effects.
Some advantages of QuinSyn plus are:
•
Superior demulsability (ability to separate from
water)
•
Less susceptible to varnish
•
Extremely low volatility
•
Excellent corrosion protection
•
Outstanding low temperature properties
•
Exceptional thermal stability
•
Excellent oxidative stability
•
Better gas-fluid separation
Typical Properties of QuinSyn Plus
ISO 46
Viscosity @ 100°F ASTM D445
46.0 cSt.
Viscosity @ 210°F ASTM D445
7.5 cSt.
Viscosity Index ASTM D2270
127
Specific Gravity 60/60
0.89
Flash Point ASTM D92
475°F
Fire Point ASTM D92
540°F
Pour Point
-58°F
Applications
QuinSyn Plus is suited for use in rotary screw air
compressors operating in harsh service conditions where
the fluid is exposed to higher temperatures for extended
periods of time. Fluid thermostat temperature settings can
be elevated to assist in reducing water content in the fluid
in high humidity applications. Please consult Quincy
Service Department for any thermostat changes.
Disposal
QuinSyn Plus is considered nonhazardous waste.
Disposal of this fluid should be done in accordance with
Local, State, and Federal regulations. Should condensate
need to be treated, Quincy’s QIOWA fluid/water
separators are required.
Fluid Analysis Program
QuinSyn Plus fluid is included in Quincy’s fluid analysis
program.
NOTICE!
To maintain extended warranty compliance, fluid
samples of QuinSyn Plus must be sent to Quincy
Compressor
®
Fluid Analysis a minimum of every
2,000 hours.
Summary of Contents for QSB 15 HP
Page 2: ......
Page 9: ...Section I General Quincy Compressor QSB T 5 MODEL IDENTIFICATION ...
Page 21: ...Quincy Compressor QSB T 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 27: ...Quincy Compressor QSB T 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 71: ...Quincy Compressor QSB T 67 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 72: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSB T QSB 15 50 HP air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 69 QSB 15 50 HP water cooled ...