Section II - Description
Quincy Compressor
®
- QSB/T
™
11
Indicators
Main Power on Light
Indicates when power from the main disconnect switch
has been turned on and there is live power at the
compressor starter and control panel. This light will
remain on as long as there is power to the unit, regardless
of the position of the selector switch.
CAUTION!
Always check power supply disconnect. The
Power-on light may be inoperable.
High Discharge Air Temperature Light
Indicates when the unit has sensed an unusually high
discharge temperature.
Air/Fluid Separator Indicator
Indicates excessive pressure differential across the air/
fluid separator element. It is used to determine separator
element change intervals.
Gauges
Hourmeter
This gauge indicates actual hours of operation.
Air Pressure Gauge
This gauge indicates air pressure available for distribution
to the service line.
CAUTION!
Gauge may not register when the unit is unloaded
or off. Make certain all air pressure is relieved
prior to servicing.
Air Outlet Temperature Gauge
This gauge indicates the temperature of the air/fluid
mixture as it discharges from the compressor. The normal
reading is 180°F-200°F.
Percent Capacity Gauge
This gauge is graduated in percent of the total capacity of
the unit. Readings taken from this gauge give an
indication of the amount of air being used.
Summary of Contents for QSB Series
Page 2: ......
Page 9: ...Section I General Quincy Compressor QSB T 5 MODEL IDENTIFICATION...
Page 21: ...Quincy Compressor QSB T 17 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 27: ...Quincy Compressor QSB T 23 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 71: ...Quincy Compressor QSB T 67 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 72: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSB T QSB 15 50 HP air cooled...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 69 QSB 15 50 HP water cooled...