Section VII - Compressor Fluids
Quincy Compressor
®
- QSB/T
™
47
Converting to QuinSyn XP
Normal Machines
A. Any QuinSyn fluid - No flush required. Drain
Compressor thoroughly while hot, including all the
low areas, fluid lines and the fluid cooler. Shut
down and lockout the machine. Change the
separator and all the filters on the compressor.
Refill the reservoir and system with a full charge of
QuinSyn XP.
B. Mineral Oils - Drain compressor thoroughly while
hot including all the low areas. Shut down and
lockout the machine. Detach lines and drain.
Inspect machine; if clean, change filters and
separator elements. Fill with QuinSyn Flush and
run machine until it reaches normal operating
temperature. Drain and refill with a fresh charge of
new QuinSyn XP. Send a fluid sample to Quincy
Compressor
®
Fluid Analysis at 200 hours.
Varnished Machines
For
slightly to extremely varnished
machines using
mineral oils or PAO fluids, flush the compressor with
QuinSyn Flush following the procedures outlined on page
45.
Converting to QuinSyn Plus
Normal Machines
A. Any QuinSyn fluid
(except QuinSyn PG)
- No
flush required. Drain Compressor thoroughly while
hot, including all the low areas, fluid lines and the
fluid cooler. Shut down and lockout the machine.
Change the separator and all the filters on the
compressor. Refill the reservoir and system with a
full charge of QuinSyn Plus.
B. Mineral Oils and QuinSyn PG - Drain compressor
thoroughly while hot including all the low areas.
Shut down and lockout the machine. Detach lines
and drain. Inspect machine; if clean, change filters
and separator elements. Fill with QuinSyn Flush
and run machine until it reaches normal operating
temperature. Drain and refill with a fresh charge of
new QuinSyn Plus. Send a fluid sample to Quincy
Compressor
®
Fluid Analysis at 200 hours.
Varnished Machines
For
slightly to extremely varnished
machines using
mineral oils or PAO fluids, flush the compressor with
QuinSyn Flush following the procedures outlined on page
45.
Summary of Contents for QSB Series
Page 2: ......
Page 9: ...Section I General Quincy Compressor QSB T 5 MODEL IDENTIFICATION...
Page 21: ...Quincy Compressor QSB T 17 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 27: ...Quincy Compressor QSB T 23 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 71: ...Quincy Compressor QSB T 67 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 72: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSB T QSB 15 50 HP air cooled...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 69 QSB 15 50 HP water cooled...