Section II - Description
10
Quincy Compressor-QSI
®
Electrical System
A diagram of the electrical system is shown in the parts
manual sent with the compressor. A wiring diagram is
also included in the control panel on all Quincy QSI
compressors.
NOTICE!
Due to continuing product improvements and
updates, it is suggested that the wiring diagram
included in the control panel be used when
servicing the electrical control.
Standard drive motors are open drip proof 1800 RPM
with a maximum ambient temperature rating of 104°F.
They are not suitable for salt laden, corrosive, dirty, wet
or explosive environments.
The QSI series compressors utilize 460V incoming power
through an across-the-line magnetic starter. A
transformer in the control panel reduces this voltage to
120 VAC for the various controls on the unit. These
controls include the selector switch, pressure switch,
timer, high air temperature safety switches, solenoid and
the various indicator lights. Other incoming line voltages
are available as options. The compressor is provided
with a NEMA 1 enclosure. Optional panels include
NEMA 4.
Air-cooled models utilize a second magnetic starter for
protection of the fluid cooler fan motor. This starter is
connected to the compressor starter through an interlock
which insures the fan motor is operating with the
compressor motor. If the fan motor starter trips out for
any reason, the compressor unit will shut down.
DANGER!
High voltage could cause death or serious injury.
Disconnect all power supplies before opening the
electrical enclosure or servicing.
Safety Sensors
Two high air temperature (HAT) sensors are standard on
the QSI units. These sensors protect the unit by sensing
unusually high temperatures and shutting the unit down.
One is located in the discharge line from the compressor
to the air/ fluid reservoir. The second is located in the top
of the air/fluid reservoir. These sensors are set to trip at
approximately 225°F. The sensors are nonadjustable.
WARNING!
Never remove, bypass or tamper with the safety
HAT switch. Failure to provide this safety feature
could cause death or serious injury and property
damage. If the compressor is shutting down due
to high discharge temperature, contact a qualified
service technician immediately.
Summary of Contents for QSI 1000
Page 2: ......
Page 7: ...This page intentionally left blank ...
Page 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Page 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Page 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Page 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Page 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Page 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Page 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Page 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Page 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Page 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Page 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Page 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Page 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Page 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Page 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Page 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Page 99: ......