Section III - Installation
Quincy Compressor-QSI
®
13
Location
Locate the compressor on a level surface in a clean, well-
lit and well-ventilated area. Allow sufficient space (four
feet of clearance on all sides and top of the compressor)
for safe and proper daily inspection and maintenance.
The entire length of the frame base must be supported.
Shim where necessary but do not use wood.
Ambient temperature should not exceed 110°F. High
ambient temperatures may result in a high air temperature
shutdown. All models are intended for indoor
installation; however, it is possible, with certain
modifications, to accommodate some outdoor locations.
Cabinet models are water-resistant but not water tight.
Sheltering from rain, snow and freezing temperatures is
mandatory.
WARNING!
Do not operate in temperatures below 32°F or
above the limits outlined in Appendix B -
Technical Data.
Do not locate the unit where the hot exhaust air from
other compressors or heat generating equipment may be
drawn into the unit. Never restrict the flow of exhaust air
from the fluid cooler or cooling fan. Heated exhaust air
must be exhausted outside to prevent high temperature
conditions in the compressor room. If the room is not
properly ventilated, compressor operating temperatures
will increase and cause a high temperature shutdown.
CAUTION!
Clean, fresh air, of sufficient quantity, is required
for proper compressor operation.
In high humidity areas, avoid placing the compressor in a
basement or other damp locations. Control the
compressor temperatures and monitor compressor fluid
for signs of water contamination. Fluid and filter
changes may need to be increased in high humidity areas.
Increased operating temperatures may be required.
CAUTION!
Removal or modification of sound insulation
could result in dangerously high sound levels.
Quincy QSI compressors are essentially vibration free,
however, some customers may choose to bolt the unit to
the floor to prevent the accidental breakage of piping or
electrical connections as a result of being bumped. Use
only lag bolts to secure the unit. Do not pull the bolts
down tight. Overtightening the lag bolts may place the
frame in a twist or bind causing breakage of fluid coolers,
piping and reservoirs.
WARNING!
Under no circumstances should a compressor be
installed in an area exposed to a toxic, volatile or
corrosive atmosphere, nor should toxic, volatile
or corrosive agents be stored near the compressor.
Piping Connections
Never join pipes or fittings by soldering. Lead-tin
solders have low strength, a low creep limit, and may,
depending on the alloy, start melting at 360°F. Silver
soldering and hard soldering are forms of brazing and
should not be confused with lead-tin soldering. Never
use plastic, PVC, ABS pipe or rubber hose in a
compressed air system.
Piping Fit-up
Care must be taken to avoid assembling the piping in a
strain with the compressor. Piping should line up without
having to be sprung or twisted into position. Adequate
expansion loops or bends should be installed to prevent
undue stress at the compressor resulting from the changes
between hot and cold conditions. Pipe supports should
be mounted independently of the compressor and
anchored, as necessary, to limit vibration and prevent
expansion strains. Piping should never be of smaller size
than the connection on the compressor unit.
Summary of Contents for QSI 1000
Page 2: ......
Page 7: ...This page intentionally left blank ...
Page 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Page 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Page 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Page 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Page 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Page 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Page 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Page 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Page 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Page 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Page 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Page 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Page 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Page 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Page 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Page 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Page 99: ......