Section VII - Compressor Fluids
30
Quincy Compressor-QSI
®
QuinSyn PG
Effective on orders entered on June 1, 2000 and later,
Quincy’s factory fill fluid changed from QuinSyn to
QuinSyn PG. Orders placed prior to June 1, 2000
shipped with QuinSyn.
QuinSyn PG is a custom blended polyalklene glycol/ester
(PAG). QuinSyn PG is an ISO 46 viscosity fluid with an
8,000 hour life under normal operating conditions (exact
fluid life is determined by the fluid sampling program)
and is the chosen fluid for Quincy’s new five-year airend
warranty effective June 1, 2000 (see Blue Alert #566).
Under extended warranty conditions QuinSyn PG fluid
life is rated at 8,000 hours or one year, whichever occurs
first.
Typical Properties of QuinSyn PG
ISO 46
Viscosity @ 100°F ASTM D445
52.4 cSt.
Viscosity @ 210°F ASTM D445
9.4 cSt.
Viscosity Index ASTM D2270
163
Specific Gravity 60/60
0.98
Flash Point ASTM D92
485°F
Fire Point ASTM D92
525°F
Applications
QuinSyn PG is the recommended fluid in high humidity
applications due to its ability to hold water. QuinSyn PG
is best suited for applications where high humidity exists
and the machine cannot be shut down to drain water from
the reservoir.
Disposal
QuinSyn PG is considered nonhazardous waste. Disposal
of this fluid should be done in accordance with Local,
State, and Federal regulations. Separation of this fluid
from condensate will require those separators designed to
handle fluid emulsions. The QIOWA fluid/water
separator is suitable for separation of fluid emulsions
such as QuinSyn PG. Please contact Quincy’s Service
Department for more details.
Fluid Analysis Program
The fluid sampling for QuinSyn PG has been extended to
2,000 hours because of the superior quality and forgiving
nature of this fluid. The new five-year extended warranty
with QuinSyn PG requires 2,000 hour sampling as a
condition of maintaining the warranty.
NOTICE!
To maintain warranty compliance, fluid samples
of QuinSyn PG must be sent to Quincy
Compressor Fluid Analysis a minimum of every
2,000 hours.
Because this fluid differs from QuinSyn, different
methods are employed to evaluate the fluid in the
sampling program. Primary concerns with this fluid are
the total acid number (TAN) and barium levels. QuinSyn
PG will not be condemned on water percentage nor
antioxidants but will be condemned on low barium and
high TAN values. The barium in the fluid acts as a
corrosion inhibitor, therefore we have set low limits for
this additive (see page 42 for limits).
Summary of Contents for QSI 1000
Page 2: ......
Page 7: ...This page intentionally left blank ...
Page 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Page 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Page 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Page 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Page 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Page 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Page 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Page 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Page 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Page 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Page 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Page 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Page 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Page 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Page 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Page 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Page 99: ......