Appendix B - Technical Data
78
Quincy Compressor-QSI
®
QSI 370
¯
¯
¯
¯
¯
S
TANDARD
°
°
°
°
°
Full Load Operating Pressure
psig
100
110
125
150
Maximum Operating Pressure
psig
115
125
140
165
Minimum Operating Pressure
psig
Æ
Æ
75
Å
Å
Maximum Ambient Operating Temperature:
Less Cabinet
°F
Æ
Æ
120
Å
Å
With Cabinet
°F
Æ
Æ
115
Å
Å
Minimum Ambient Operating Temperature
°F
Æ
Æ
32
Å
Å
Compressor Drive Motor
HP
Æ
75
100
Å
Rotor Diameter
mm
Æ
Æ
204
Å
Å
Male Rotor Speed
rpm
Æ
1785
1790
Å
Female Rotor Speed
rpm
Æ
1190
1193
Å
Rotor Tip Speed
M/sec.
Æ
19.07
19.12
Å
Inlet Capacity
acfm
372
370
368
364
Displacement at Operating Speed
cfm
Æ
403.1
404.2
Å
Volumetric Efficiency
%
92.3
91.5
91
90.1
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
2808
2957
3184
3581
Aftercooler
BTU/min.
Æ
Æ
522
Å
Å
Aftercooler Approach (standard conditions)
°F
Æ
Æ
3-5
Å
Å
Maximum Allowable Static Backpressure
in./H
2
O
Æ
Æ
0.125
Å
Å
Fan Motor
HP
Æ
Æ
3
Å
Å
Fan Motor
rpm
Æ
Æ
1750
Å
Å
Fan Flow
cfm
Æ
Æ
6800
Å
Å
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
Æ
Æ
40-100
Å
Å
Vent Fan Motor
HP
Æ
Æ
1/9
Å
Å
Aftercooler Approach to Cooling:
Water Temperature
°F
Æ
Æ
13-18
Å
Å
Water Flow less Aftercooler at: 50°F
gpm
Æ
4.7
5.5
Å
70°F
gpm
Æ
7.1
8.9
Å
90°F
gpm
Æ
15.2
24.6
Å
Water Flow with Aftercooler at: 50°F
gpm
Æ
6.2
7.3
Å
70°F
gpm
Æ
9.2
11.5
Å
90°F
gpm
Æ
19.4
29.5
Å
Compressor Fluid
Total Fluid Capacity
gallons
Æ
Æ
15
Å
Å
Reservoir Fluid Capacity
gallons
Æ
Æ
11
Å
Å
Fluid Flow
gpm
Æ
Æ
24.5
Å
Å
Typical Fluid Carryover
ppm
Æ
Æ
1.5-5
Å
Å
Normal Airend Discharge Temperature
°F
Æ
Æ
175-195
Å
Å
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
Æ
Æ
83/83
Å
Å
Standard Cabinet (AC/WC)
dB(A)
Æ
Æ
79/79
Å
Å
Low Sound Cabinet (AC)
dB(A)
Æ
Æ
76
Å
Å
Summary of Contents for QSI 1000
Page 2: ......
Page 7: ...This page intentionally left blank ...
Page 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Page 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Page 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Page 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Page 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Page 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Page 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Page 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Page 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Page 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Page 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Page 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Page 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Page 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Page 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Page 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Page 99: ......