Section VIII - Service Adjustments
110
Quincy Compressor-QSI
®
half so that it reads from the face of the motor cou-
pling half.
2) Position the indicator on the side of the coupling.
3) Rotate the coupling halves together, 180° in the
direction of the compressor rotation. The indica
-
tor reading in this position is the amount of angular
misalignment.
4) Loosen the motor mounting bolts and move the mo-
tor slightly with a pry bar or soft mallet so that when
step C is performed, the indicator reading is within
machine specification.
NOTICE!
Do not lubricate capscrew threads. If capscrews
are used, apply thread-locking adhesive. These
are special bolts. Do not substitute.
Parallel Misalignment Viewed from the Top
1) Mount the dial indicator on the compressor coupling
half so that it reads from the outside surface of the
motor coupling half.
2) Position the indicator on the side of the coupling.
3) Rotate the coupling halves together, 180° in the
direction of the compressor rotation. The indica
-
tor reading in this position is the amount of parallel
misalignment.
4) Loosen the motor mounting bolts and move the mo-
tor slightly with a pry bar or soft mallet so that when
step C is performed, the indicator reading is within
machine specifications.
NOTICE!
Always recheck all measurements since one align-
ment procedure may effect another.
Reinstall the other coupling half and torque all
mounting bolts. Before placing the unit in opera-
tion, replace the drive guard and clear the area
of all tools.
Drive Coupling Specifications
Model*
Alignment Angular
Specifications
Element Bolt
Element
Bolt
Parallel
Size
Torque
1000-1500
0.005”
0.010”
1/2”
70 ft/lbs.
*Standard 110 PSIG models only