Section IX - Troubleshooting
Probable Causes:
Corrective Action:
116
Quincy Compressor-QSI
®
Replace fluid filter element(s).
Maximum ambient for proper operation is
listed in data sheet. Ventilate room or relo
-
cate compressor.
Correct rotation is with the fan pushing the
air through the cooler. Reverse motor start
-
er leads L
1
and L
2
.
Use recommended fluids only. Refer to “Com
-
pressor Fluids” section of this manual.
Clean or replace as necessary.
Repair or replace as necessary.
Check and replace as necessary.
Contact an authorized Quincy distributor.
If faulty air filter elements, replace them. If
air filter is inadequate for the environment,
relocate the intake air to a clean source.
Replace fluid filter element.
Correct in accordance with the instruction
in “Fluid Breakdown” section of the trouble
-
shooting guide.
Use genuine Quincy replacement elements
only.
Operate compressor at recommended reservoir
Frequent Air/Fluid Separator Clogging (continued):
Mixing different grades or types of fluids
Incorrect fluid
Contaminated fluid
Fluid Discharge Out Blowdown Valve:
Too high fluid level in reservoir
Air/fluid reservoir blows down too fast
Inlet valve not closing completely
Frequent Fluid Filter Clogging:
Faulty Indicator
Incorrect fluid filter
Faulty, incorrect or inadequate air filter
Fluid breakdown
System contamination