Section VII - Compressor Fluids
94
Quincy Compressor-QSI
®
QuinSyn XP
Effective on orders entered on June 1, 2000 and later,
Quincy Compressor began offering our new long life
synthetic fluid, QuinSyn XP.
QuinSyn XP is the new
factory fill for high pressure units (defined as units over
125 psig full flow). QuinSyn XP replaces QuinSyn HP 68
as our high pressure fluid and is totally compatible with
QuinSyn HP 68 (the fluids can be mixed together with ab
-
solutely no problems). Aftermarket pail and drum orders
for QuinSyn HP 68 will be filled with QuinSyn XP.
QuinSyn XP is a custom blended polyolester (POE) fluid
ideally suited for rotary screw air compressors. QuinSyn
XP is an ISO 68 viscosity fluid with a 12,000 hour life at
100 & 125 psig full flow under normal operating condi
-
tions and 8,000 hours as a high pressure fluid (exact fluid
life is determined by the fluid sampling program). Quin
-
Syn XP is the only fluid available with Quincy’s ten-year
airend warranty (see Blue Alert #566).
Typical Properties of QuinSyn XP ISO 68
Viscosity @ 100°F ASTM D445
60.0 cSt.
Viscosity @ 210°F ASTM D445
9.8 cSt.
Viscosity Index ASTM D2270
131
Specific Gravity 60/60
0.95
Flash Point ASTM D92
570°F
Fire Point ASTM D92
645°F
Applications
QuinSyn XP is designed for applications where the fluid
is exposed to elevated temperatures for extended periods
of time. Fluid thermostat temperature settings can be
elevated to assist in reducing water content in the fluid
in high humidity applications. Consult Quincy’s Service
Department before making thermostat changes.
Disposal
QuinSyn XP is considered nonhazardous waste. Disposal
of this fluid should be done in accordance with Local,
State, and Federal regulations. Should condensate need
to be treated, Quincy’s QIOW fluid/water separators are
required.
Fluid Analysis Program
QuinSyn XP will be analyzed similar to QuinSyn
although the primary concern is the total acid number
(TAN). Supplemental “on site” TAN kits will be appli
-
cable to this fluid as well as QuinSyn PG.
NOTICE!
To maintain extended warranty compliance, fluid
samples of QuinSyn XP must be sent to Quincy
Compressor Fluid Analysis a minimum of every
2,000 hours.
Summary of Contents for QSI Series
Page 2: ......
Page 7: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION...
Page 62: ...Section IV Operating Procedures 60 Quincy Compressor QSI 1 Week Timer 2 Remaining Running Time...
Page 79: ...Section IV Operating Procedures Quincy Compressor QSI 77...