Page 10
Biasi SG Pro Series
USE ONLY THE LISTED BOILER SYSTEM COMPONENTS AND
SPECIFIED OIL AND GAS BURNER COMPONENTS SUPPLIED WITH
THE BIASI SG PRO BOILER.
Please refer to figures below for Barometric Damper location (gas burners only) and to the
right for the proper location of the trim components.
Barometric Damper w/
Manual Reset Spill Switch
(Gas Burner Only)
BIASI SG
T-handle
Gas Cock
Alternative
Location
Drip Leg
Gas Train
Positive Pressure
Gas Fired
4.1 Boiler Trim Components
Union
Trim Kit Components:
1 — Control panel with temperature
and pressure gauges and
Hydrolevel Touch Panel control
1 — Immersion well
1 — 30 PSI pressure relief valve
1 — ¾” Boiler drain
1 — 12”x12” Cera-fiber blanket
1 — Burner mounting hardware
1 — ¾” X 3” Nipple
1 — ¾” 90
°
Elbow
1 — Double Acting Barometric
Damper with Manual Reset Spill
Switch
(Gas systems only)