Appendix B - Technical Data
QGB 50
Full Load Operating Pressure
psig
100
125
150
Max. Operating Pressure
psig
115
140
165
Min. Operating Pressure
psig
75
75
75
Max. Ambient Operating Temp.
°F
122
122
122
Min. Ambient Operating Temp.
°F
40
40
40
Compressor Drive Motor
Nameplate hp
50
Inlet Capacity
acfm
238
206
186
Service Line Connection Size
In. (FLG)
1.25
1.25
1.25
Rotor Diameter
mm
127.5
127.5
127.5
Male Rotor Speed
rpm
4276
3835
3540
Male Tip Speed
m/sec
28.5
25.6
23.6
Aftercooling Data
Heat Rejection - Fluid Cooler
btu/min
1789
Aftercooler
btu/min
281
Aftercooler Approach to Cooling
Air (@ std. conditions)
°F
13.3
Max Static Backpressure
in. H20
0.125
Fan Motor
Nameplate hp
1
Fan Motor
rpm
3525
Fan Flow
cfm
2430
Compressor Fluid Data
Fluid Flow
gpm
15
16.7
18.4
Total Fluid Capacity
gal
8.5
Reservoir Fluid Capacity
gal
5.4
Normal Airend Discharge Temp.
°F
190
Typical Fluid Carryover
ppm
<3
Sound Data (at 1 meter)
Unenclosed
dB(A)
82
Standard Enclosure
dB(A)
75
Energy Consumption (air-cooled)
Full Load Drive Motor HP
Bhp
54.4
54.4
54.5
Unloaded Drive Motor HP
Bhp
9.5
9.5
9.5
Fan Motor HP
Bhp
0.82
0.82
0.82
FL Drive Motor Consumption
kW
43.83
43.62
43.7
FL Fan Motor Consumption
kW
0.77
0.76
0.76
Total Package Consumption
kW
44.6
44.38
44.46
Total Package Specific Power
kW/100 cfm
18.7
21.5
23.9
bhp/100 cfm
23.2
26.8
29.7
Dimensions
Length
in (mm)
72 (1830)
Width
in (mm)
34 (834)
Height
in (mm)
69.5 (1765)
90
Quincy Compressor-QGB
™
Back to Table of Contents