Section VI - Compressor Fluids
Cleaning and Flushing with QuinSyn Flush
normal Machines
To flush clean machines presently using:
Mineral Oils -
(A) - Drain compressor thoroughly while
hot including all the low areas.
- Shut down and lockout the
machine.
- Detach fluid lines and drain.
- Inspect the machine;
- if clean, change filters and separator
elements and proceed as follows:
• Fill with QuinSyn Flush and run machine
until it reaches normal operating
temperature.
• Drain the QuinSyn Flush and discard
in accordance with all local, state and
federal disposal regulations.
• Change the separator element and all
filters.
• Refill with a fresh charge of the QuinSyn
fluid selected for your machine.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
Polyalklene glycols (PAG) or Silicone -
• Drain compressor thoroughly as in (A).
• Fill machine with QuinSyn Flush and run
for 500 hours.
• Send fluid sample to Quincy
Compressor Fluid Analysis to determine
if further flushes are needed.
• Continue compressor operation until
results of fluid analysis are reported.
• Once the analysis indicates the machine
is clean, drain the flush, change the
separator element and all filters, and fill
with the QuinSyn fluid selected for your
machine.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
54
Quincy Compressor-QGV Series
Summary of Contents for QGV-100
Page 2: ......
Page 6: ......
Page 17: ...Section II Description This page intentionally left blank Quincy Compressor QGV Series 11 ...
Page 74: ...Appendix A Dimensional Drawings QGV 50 air cooled 68 Quincy Compressor QGV Series ...
Page 75: ...Appendix A Dimensional Drawings QGV 50 water cooled Quincy Compressor QGV Series 69 ...
Page 76: ...Appendix A Dimensional Drawings QGV 75 100 air cooled 70 Quincy Compressor QGV Series ...
Page 77: ...Appendix A Dimensional Drawings QGV 75 100 water cooled Quincy Compressor QGV Series 71 ...
Page 78: ...Appendix A Dimensional Drawings QGV 150 200 air cooled 72 Quincy Compressor QGV Series ...
Page 79: ...Appendix A Dimensional Drawings QGV 150 200 water cooled Quincy Compressor QGV Series 73 ...
Page 89: ......