Section III - Installation
Compressor Rotation
Compressor rotation must be checked
prior to start-up. Proper rotation is
clockwise (as viewed from the power-
input end). The power-input end of the
compressor is marked with an arrow
noting the proper rotation. Operating the
compressor in incorrect rotation will result
in extreme damage to the compressor
and warranty coverage will be voided. To
check for proper rotation, jog the starter
button, allowing the motor to turn 2 or 3
revolutions. Observe the drive element
for correct direction. If incorrect rotation is
observed, lock out power supply, reverse
electrical leads L
1
and L
3
at the motor
starter. Recheck for correct rotation.
Alternate method to check rotation is to
remove drive coupling element prior to
bump starting the motor.
Fan Rotation
QSI compressors use a centrifugal fan.Fan
rotation is checked making sure the fan
ratation matches the arrow decal. The fan
must rotate in the direction indicated by
the arrow.
NOTICE!
Never assume the fan rotation
is correct based on the induced
air flow across the coolers. A
centrifugal fan can pull the airflow
across the coolers when rotating
in either direction, however,
incorrect rotation will cause a
high discharge temperature.
15
Summary of Contents for QGV-20
Page 2: ......
Page 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Page 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Page 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Page 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Page 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Page 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Page 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Page 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Page 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Page 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Page 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Page 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Page 91: ......