SYSTEM INDICATORS: 

 

RUN STATUS

 indicates that the compressor is in a run state.  A steady light indicates that the 

compressor is running.  If this light is 

flashing

, and the compressor is in a stopped condition, the 

compressor will 

re-start at any time

.  This also indicates that the compressor is about to start, when the 

auto-restart option is enabled. 
 

LOAD/UNLOAD:

 The left-most digit on the numeric display will show 'L' when the compressor is 

loaded, and 'U' when unloaded. 
 

PROGRAM SETUP MENUS 

 
The program setup menus are accessed by holding both the UP and DOWN keys in, until the LED lamps 
on the left start to flash.  Release the UP and DOWN keys, and when the numeric display shows  -00- 
flashing, use the up key to select the desired menu (1, 2, and 3 are user menus). 
There is a time limit to select the menu number.  If this time period is exceeded, the control will return to 
the standard display mode. 
 

NOTE:

 

The nomenclature on the decal beside the LED's does NOT represent the function of the LED in 

these menus. 

 

MENU 01: BASIC OPERATING ADJUSTMENTS. 

 

LED 1:

 Use the MENU key to select the UNLOAD pressure, as indicated by a 'U' at the left-most digit.  

Use the UP or DOWN keys to adjust.  

NOTE: Value is saved when display is no longer blinking. 

 
Use the MENU key to then select the LOAD pressure, as indicated by an 'L' at the left-most digit, Use the 
UP or DOWN keys to adjust. 
 

LED 2:

 This allows the adjustment of the Wye/Delta (Y/D) time on the contactor: this is set to optimum 

at the factory.  This should be set to allow the motor to reach full speed before the contactors switch from 
wye to delta connection. 
 

LED 3:

 This is the AUTO-DUAL timer setting.  This is how long the compressor will run in an unloaded 

state before shutting down (Minutes).  When the delivery pressure falls  below the LOAD setting after 
shutting down, the compressor will start up automatically.  A 'd' will show in the left-most digit of the 
display to indicate this is the Auto-Dual timer. 
 

LED 4:

 This is the auto-restart delay in Seconds.  The compressor will  delay this length of time on 

power-up, before automatically starting.  An 'r' will show at the left-most digit.  Set to 0 if auto restart is 
NOT required.  

NOTE:

 

AUTO-RESTART refers to the automatic starting of the compressor on power 

application. 

 

Summary of Contents for QMB Series

Page 1: ...tion Quincy QMB T Series Electronic Control Instruction Manual This manual contains important safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting to operate or perform maintenance on this compressor ...

Page 2: ......

Page 3: ...n with the POWER lamp on showing that the control board has power and the SYSTEM PRESSURE LED will be lit showing the pressure on the numeric display NOTE A flashing on the digit display accompanied with an LED on the left signifies a faulty sensor either the pressure transducer or the temperature probe A FAST blinking LED indicates that the labeled function has been tripped an over pressure condi...

Page 4: ...f no major faults are present open pressure sensor temperature sensor high temperature condition or overload NOTE The RUN STATUS LED will be ON to show that a start cycle is in progress The compressor will not start if the line pressure is above the load point the compressor will start when the line pressure drops below the load point If the compressor is waiting to start the Run Status LED will f...

Page 5: ...RATING ADJUSTMENTS LED 1 Use the MENU key to select the UNLOAD pressure as indicated by a U at the left most digit Use the UP or DOWN keys to adjust NOTE Value is saved when display is no longer blinking Use the MENU key to then select the LOAD pressure as indicated by an L at the left most digit Use the UP or DOWN keys to adjust LED 2 This allows the adjustment of the Wye Delta Y D time on the co...

Page 6: ...e hours setup The display will show the hours remaining alternating with FLu On servicing the fluid filter or taking a sample this counter should be re set to the desired service interval The LED s described above will blink when the service intervals reach 00 in the main running display As before the setting is saved when the display reading is steady MENU 03 DISPLAY UNITS AND MODEL TYPE LED 1 Se...

Page 7: ...h if the main contactor fails to close properly or fails to open in a controlled shutdown 3 OVERLOAD This LED will light if the motor overload has tripped LED MESSAGE INDICATORS 1 Excessive pressure Error Top LED flashes fast 2 Separator Element clogged Second LED flashes slowly 3 Air Filter timer expired The message AIRF flashes on the display 4 Excessive Temperature Third LED flashes slowly 5 Te...

Page 8: ...he Teflon bushing is recommended any time a transducer is replaced Install new Teflon bushing and transducer Connect transducer wires to microprocessor and reinstall wire channel cover Replacing electronic control NOTE Prior to touching any portion of the printed circuit board you will need to ground yourself to remove any static electricity using a grounding wrist strap After assuring the compres...

Page 9: ...7 WIRING DIAGRAM ACROSS THE LINE STARTING ...

Page 10: ...8 WIRING DIAGRAM WYE DELTASTARTING ...

Page 11: ......

Page 12: ...ll help keep you in business Call for Authorized Quincy Service Quincy Compressor T r u e B l u e R e l i a b i l i t y SM Rotary Vacuum Systems 251 937 5900 Reciprocating Systems 217 222 7700 Nearest Distributor 888 424 7729 E mail trueblue quincycompressor com Discover www quincycompressor com 2003 Quincy Compressor an EnPro Industries company EnPro Industries company EnPro Industries All Rights...

Reviews: