8. Installation & start up
When installing and operating explosion-proof electrical systems the relevant installation &
operating regulations must be observed at all times (e.g. Self-assessment,
IEC/EN 60079-14 and national regulations).
Assembling / Dismantling
Threaded Line Bushing
The drilled and tapped (threaded) entry of a flameproof enclosure in which the threaded
line bushing is installed must comply with IEC/EN 60079-1; section 5.3.
Thread pitch
≥ 0,7mm
Grade
ISO 965-1/-3 medium (m)
Number of threads
≥ 6
Thread depth of enclosure:
≤ 100cm³ ≥ 5mm
≥ 100cm³ ≥ 8mm
Fixing details for standard application:
Fixing details for application with vibrations:
Also applicable for threaded blind plug / blanking plug and twin-path version.
Locknut
Enclosure wall
Line bushing
Enclosure wall
Line bushing
Locknut
Spring washer
Enclosure wall
Line bushing
Adhesive