P/N 480-0049-00-13
3-14
Chapter 3: Installation
Figure 3-10
Port Settings
Window
6. From the
Bits Per Second
drop down list box, choose
38400
.
7. From the
Data Bits
drop down list box, choose
8
.
8. From the
Parity
drop down list box, choose
None.
9. From the
Stop bits
drop down list box, choose
1
.
10. From the
Flow control
drop down list box, choose
None
.
11. Press the
Tenor AS
power switch to
On
. After the bootup sequence, the login prompt will appear.
12. Enter a login name. The default login name is
admin
.
13. Enter a password. The default password is
admin
. (Once you are up and running, changing the
password is a good idea for security purposes). Step through each of the following parameters
and enter the correct values for your installation: IP address, Subnet Mask and Default Gate-
way.
14. At the
Quintum
prompt, type
ei
to reach the Ethernet prompt and then type
config
to change to the Con-
figuration mode.
15. To set the IP address, type
set ipa
followed by the IP address.
16. To set the Subnet Mask, type
set subnetmask
, followed by the subnet mask.
17. Type
siprd
to change to the Static IP Route Directory.
18. To set the Default Gateway IP, type
change 1 g
followed by the IP address for the default gateway IP.
19. Type
submit
.
20. Type
maint
to reach the maintenance mode and then
mc
. Type
reset
. A confirmation message will ask if
you want to reset the unit. Type
yes
to reset the unit. The reboot enables the Tenor to incorporate the new
settings.