background image

ISO

  

|

  4

FEATURES AND SPECIFICATIONS

FEATURES 

•  Humidity-sensing fan shuts off after bathroom is steam-free

•  Motion-activated night light functions in dark environments 

and shuts off two minutes after motion ceases

•  Fan is ultra-quiet

•  Bright, fluorescent light for general bathroom illumination

TYPICAL INSTALLATION

FAN HOUSING

ROOF

DUCT

OR

EXTERIOR WALL

SPECIFICATIONS 

•  Grill dimensions: 13” x 13” x 1.5” (33 cm x 33 cm x 3.8 cm)

•  Housing dimensions: 97/8” x 97⁄8” x 8” 

(25.1 cm x 25.1 cm x 20.3 cm)

•  Duct diameter: 4” (10.2 cm)

•  Sound output: 1.3 sones

•  Airflow: 90 CFM

•  Exhaust fan speed: 790 RPM

•  Weight: 12 lbs. (5.4 kg)

•  Electrical rating: 120V / 60Hz / 0.3A / 36W (fan only),  

120V / 60Hz / 0.63A / 75.6W (fan and lights)

•  Assembled weight: 12 lbs. (5.4 kg) 

 
Requires two (2) 13W (60W equivalent) GU24 base 
CFL bulbs and one (1) 7W C7 intermediate base 
incandescent bulb (not included).

Make sure the vent/duct is venting outward 
and not up into the ceiling.

Summary of Contents for ISO

Page 1: ...ilateur aspirant activ par la vapeur et veilleuse activ e par le mouvement extractor extractor activado por vapor y luz nocturna activada por movimiento ISO For service questions contact Quirky at 1 8...

Page 2: ...ISO 2...

Page 3: ...BOX SAFETY INFORMATION PREPARATION WIRING INSTRUCTIONS INSTALLATION INSTRUCTIONS NEW CONSTRUCTION EXISTING CONSTRUCTION WALL SWITCH SPECIFICATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY UL507...

Page 4: ...SPECIFICATIONS Grill dimensions 13 x 13 x 1 5 33 cm x 33 cm x 3 8 cm Housing dimensions 97 8 x 97 8 x 8 25 1 cm x 25 1 cm x 20 3 cm Duct diameter 4 10 2 cm Sound output 1 3 sones Airflow 90 CFM Exhau...

Page 5: ...ng wood screw 6 actual size short machine screw 4 actual size long machine screw 2 actual size switch suspension bracket II suspension bracket III metal rim and glass bell ceiling plate IN THE BOX NOT...

Page 6: ...control dimmer switch or certain timers Mechanical timers are not solid state devices Do not install in a cooking area CAUTION For general ventilating use only do not use to exhaust hazardous or explo...

Page 7: ...rdware store The hole for installation is not sized to the fan unit use the following dimensions so that the Iso ceiling panel will rest flush against the ceiling DIMENSION REQUIREMENTS Ceiling Openin...

Page 8: ...n s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burn...

Page 9: ...BOARD CEILING BOARD JOIST BRACKET 5 Using wire nuts provided connect house wires to ventilating fan wires black to black white to white green to green refer to wiring diagram on page 7 CAUTION If you...

Page 10: ...housing EXISTING CONSTRUCTION 2 Make sure the existing hole is at least 10 x 10 25 4 cm x 25 4 cm but smaller than 13 x 13 33 cm x 33 cm 3 Cut into the ceiling about 2 5 cm wide to fit drill bit refer...

Page 11: ...al wire which is white and potentially a grounding wire which is green or bare copper There may be other wires in the switch box but you are only dealing with the ones connected directly to the switch...

Page 12: ...use solvents thinner or harsh chemicals for cleaning the fan Do not allow water to enter the motor Do not immerse plastic parts in water over 140 F 60 C 1 Unscrew the four 4 screws and carefully remov...

Page 13: ...cloth with dish detergent wipe the fan housing and dry with a cloth DO NOT USE abrasive cloth steel wool pads or scouring pads 3 Replace the ceiling panel by following steps 7 13 under installation i...

Page 14: ...n 18 45 7 cm to the fan discharge Fan body not securely attached Be sure the fan is securely attached to your ceiling joists Fan duct is being obstructed at some point including end of duct Check the...

Page 15: ...Night light sensor is not registering movement Using a damp cloth or rag clean off fan s faceplate including the small half sphere sensor Make sure the hanging part of the unit is not obstructing the...

Page 16: ...implied warranties or incidental consequential or other damages so the above exclusions and limitations may not apply to you This device complies with Part 15 of the FCC Rules Operation is subject to...

Page 17: ...ection 64A Installation Instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified pe...

Page 18: ...or service and support email us at questions quirky com or call 1 866 5QUIRKY 1 866 578 4759 R INS ISO1 X rev073014 For service questions contact Quirky at 1 866 578 4759 For sales inquiries contact S...

Reviews: