Operating manual
water 5.5
Bedienungsanleitung
Elektronischer Wasserzähler
Operating manual
Electronic water meter
Notice d’utilisation
Compteur d‘eau électronique
Instrucciones de operación
Contador electrónico de agua
Istruzioni per l‘uso
Contatore d’acqua elettronico
EN
EN
2
2 sec
m
3
31
5 sec
m
3
31
0.5 sec
m
3
31
5 sec
m
3
31
5 sec
m
3
31
2 sec
m
3
31
2 sec
m
3
31
m
3
31
2 sec
m
3
31
0.5 sec
Error code (1)
Error date (2)
Cum. volume (3)
Last due date (5)
Consumption on
last due date (6)
Checksum (7)
Radio mode (8)
Segment test (4)
Display on
Display off
These display levels only
appear when a device
error has occurred.
These display levels
can be switched on and
off individually via the
software Q suite 5.
Display loop
EN
3
EN
(1) Error code
The error code display is only shown when an error exists. Each digit
stands for a reason for the error according to the table on page 4. Sever-
al errors can occur at the same time.
If a leak has been detected in the system, the letter sequence "LEAC"
is displayed. The display goes off automatically as soon as the leak has
been eliminated.
(2) Error date
The display only appears if there is a serious functional problem. The
date is shown on which the meter's functional problem occurred. If a
serious error occurs, the error date indicates the time at which the con-
sumer displays were "frozen".
The arrow on the display shows the respective direction of fl ow.
(Arrow to the right - positive fl ow, arrow to the left - negative fl ow)
m
3
31
m
3
31
m
3
31
"LEAC" can only be dis-
played if no error code (1)
exists.
Error code | Leak detection | Error date
EN
EN
4
Error
code
Description of the error
Measures / notes
LEAC
Leak in the system.
Check the pipe system, elimi-
nate the leak.
The error is automatically reset
when the leak is eliminated.
0
Negative direction of fl ow.
Check meter installation/direc-
tion of fl ow
2
Operating hours expired.
Device should be replaced
during the next service ap-
pointment.
3
Hardware error.
Device must be replaced!
4
Permanently stored error.
Device must be replaced!
b
Communication via OPTO too
often per month.
The stoppage is cancelled
automatically from one month
to the next!
c
Communication via M-Bus too
often per month.
The stoppage is cancelled
automatically from one month
to the next!
d
Flow too high.
Check installation conditions!
If necessary, replace the meter
by a counter with larger Q
3
.
f
Device was without voltage
supply briefl y. All parameter
settings are lost.
Device must be replaced!
Troubleshooting
EN
5
EN
(3) Cumulated volume
The cumulated volume is displayed in m
3
with three decimal places.
This example shows 1823 litres.
(4) Segment test
This display should ensure that all display segments work perfectly.
All the segments appear on the display for 0.5 seconds, and the
complete display goes dark for a further 0.5 seconds.
Then the display jumps to the next display step.
(5) Last due date
This display “
Last due date
” shows the date on which the cumulated
volume was saved. (Date of the last due date)
The display “
Not yet reached
” shows the date without the year number
because the date of the key date has not yet been reached.
m
3
31
m
3
31
m
3
31
m
3
31
m
3
31
Not yet reached
Cum. volume | Segment test | Last due date
EN
EN
6
(6) Consumption on last due date
This display shows the cumulated volume on the last due date.
If the fi rst due date has not been reached yet, "0.000" appears on the
display.
(7) Checksum
The checksum is formed from the cumulated volume on the last due
date, the date of the due date and the device number.
This display can be used for later checks on the readout values (e.g. for
postcard readouts).
(8) Radio mode
This display shows which radio mode the device is operated in.
FC = C-mode
FS = S-mode
m
3
31
m
3
31
m
3
31
Consumption on last due date | Checksum | RF-mode