FOM5-00W
A-DE0-B01G2-A
● 1.12.20 / V 1.00
EN
7
EN
Activation and integration in radio systems
The radio transmitter of the Q water 5.5 is automatically activated after a
fl ow of 50 litres, but without transmission of installation telegrams.
Alternatively, the radio transmitter can also be activated by means of
IrDA stick WFZ.PS or by the parameter setting software Q suite 5.
Q walk-by (mobile data recording)
12 minutes after the radio transmitter has been activated, the Q water 5.5
transmits control telegrams so that a control readout can be carried out
after all devices have been installed. Then the Q water 5.5 transmits
regular walk-by telegrams.
Q AMR (automatic data recording)
After the radio transmitter has been activated, the Q water 5.5 transmits
installation telegrams for integration in the AMR network. Then the
Q water 5.5 transmits regular data telegrams and statistics telegrams
depending on the radio mode set.
Parameter-setting possibilities
The parameters for the Q water 5.5 are set using the parameter setting
software Q suite 5. The following settings are just some of those which
can be done via the Q suite 5:
•
Switch display levels on and off
• Activation of leak detection and setting of the threshold value for leak
detection
• Setting of the next due date
•
Switchover of radio mode (C-mode ↔ S-mode)
• walk-by settings:
- Transmission period
- Transmission-free days (S-mode only)
- Transmission delay (S-mode only)
Integration in radio systems
EN
EN
8
Q node 5.5 - Network node
Data provision via radio and cable
Q gateway 5 - Smart Meter Gateway
Data provision via GPRS/EDGE/
UMTS/HSPA
Remote query
Q AMR
Q SMP
Remote query via
GPRS/EDGE/
UMTS/HSPA
Q walk-by
Radio system description
EN
9
EN
Transmission behaviour in C-mode
walk by
AMR
(1)
every 112 seconds
every 7.5 minutes
10 hours per day
(8 am - 6 pm)
24 hours per day
365 days per year
365 days per year
(1)
OMS-conform data telegrams
Transmission behaviour in S-mode
walk by
AMR
every 128 seconds
every 4 hours
10 hours per day
(8 am - 6 pm)
24 hours per day
monthly 4 readout days from the
fi rst of each month
or annually 48 days after due date
7 days per week
or
365 days per year
Radio modes Q AMR and Q walk-by
EN
EN
10
Norms and standards
Conformity
see EU Declaration of Conformity
Environmental conditions
Protection class
III according to EN 61140
Protection rating
IP65/IP68 according to EN 60529
Transport
-25 °C bis +70 °C, Relative air humidity:
max. 95 %, without condensation
Storage
-5 °C bis +45 °C, Relative air humidity:
max. 95 %, without condensation
Operation
+5 °C bis +55 °C, Relative air humidity:
max. 95 %, without condensation
Radio
Radio modes
S-mode (Q AMR, Q walk-by)
C-mode (Q AMR, Q walk-by)
Frequency range
S-mode (868.30 +/- 0,30) MHz
C-mode (868.95 +/- 0,25) MHz
Transmission power
Typically 10 dBm, max. 14 dBm
Duty Cycle
< 1 % (50ms/128 s)
Data transmission to
EN 13757-4
Security of information technolog equipment
EN 62368-1
Energy supply
Operating voltage
DC 3 V
Battery service life
1 year storage, 10 years radio operation,
1 year reserve
Battery
Lithium content per battery 0,58 g
Battery type
CR AA
Batteries per unit
1x
Technical data
EN
11
EN
Notes