11/12
www.qundis.com
Network nodes with gateway WTX16.GSM/IP/MOD-1
10.09.2009
WTX16.IP
The WTX16.IP network node features an Ethernet interface, which connects to the outside
world via an RJ45 connector, where the net-work cable is to be connected.
The distance to the network conduit box may not exceed 2 meters.
It is possible, to choose fixed or dynamic (DHCP) IP addresses for WAN communication.
The transmission in WAN can be done secured by SSL or unsecured.
Parameter setting
The WTX16.GSM, WTX16.MOD and WTX16.IP network nodes are parameterized with the
ACT21 software. The scope of delivery of the software includes an RS-232 cable for con-
necting the PC to the gateway.
Sealing
On completion of commissioning, secure the network node with the seal provided. Insert the
seal in the opening to the right of the network node.
Safety guidelines
After opening the housing, certain parts of the device / system that become accessible carry
dangerous voltage. Only qualified staff may interfere with such devices / sys-tems.
To ensure correct and safe operation, the pro-duct must be adequately shipped, stored,
installed, operated and maintained.
Staff dealing with the product must be familiar with all potential hazards and maintenan-
ce measures in accordance with the instructions given in this document.
It must be possible to disconnect the device from the power supply at an easily acces-
sible point (e.g. a switch in the power cable)
The connection cable has to be protected by an appropriate fuse. Whenever performing
any work on the WTX16..., disconnect the device from the mains supply.
Non-observance of these warning notes can lead to personal injury or damage to
property!
The local regulations for electrical installations and wireless systems must be complied with.
Pursuant to the "Verordnung über Allgemeine Bedingungen für die Elektrizitätsversorgung
von Tarifkunden (AVBEltV)" of the Ministry of Economics, electrical installations behind the
house’s fused connection may only be erected, extended, changed and maintained by elec-
trical installers that are registered with an electric utility. They must ensure that the general
technical regulations and legal safety regulations are complied with.
M-Bus connection
Each network node has a plug terminal for a permanently installed M-Bus connection. A
fitting plug is included.
RESET
MODE
permanently connected M-Bus
max. 5 unit loads
temporary
M-Bus connection
(WTX16.GSM, WTX16.IP:
connection to gateway)
In Germany: