background image

2/12 

www.qundis.com Network 

nodes 

with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009 

Functions 

  Reception and storage of the data transmitted by the consumption meters 

  Automatic creation of a network with up to 12 WT…16 (with a maximum of 500 consump-

tion meters) 

  Passing on all relevant consumption values to all WT…16 on the network 

  Communication via the QUNDIS gateway 

Network node versions 

The WT…16… network node is a component of the Q AMR system and has been designed 
for exclusive use with that system.  
The network node with integrated gateway is available in a number of versions for different 
applications: 
 

Type code 
(ASN) 

Application Integrated 

M-Bus master 

Max. number of 
meters 

WTX16.GSM 

Network node with gateway  
remote readout via GSM 

yes,  
5 additional  
unit loads 

2000 

WTX16.IP 

Network node with gateway  
remote readout via Ethernet 

yes,  
5 additional  
unit loads 

2000 

WTX16.MOD-1 

Network node with gateway  
remote readout via GSM or GPRS*) 

no 500**) 

*) The use of the GPRS application requires certain provisions by the network operator. To 

use the GPRS option the user has to conclude a special contract with the service pro-
vider. 

**) WTX16.MOD-1 has no M-Bus master. It cannot be used to interconnect different net-

works. 

Combinations 

All network nodes with gateway can be used in any combination with other QUNDIS network 
nodes as long as the maximum number of 12 nodes per network is not exceeded. 
Network nodes with gateway and integrated M-Bus master (WTX16.GSM and WTX16.IP) 
can read external M-Bus meters complying EN1434/3. 

Summary of Contents for WTX16.GSM

Page 1: ...been designed for use in buildings to create a radio network for receiving and storing the data transmitted by the consumption meters installed in the building Communication between several net work n...

Page 2: ...ster Max number of meters WTX16 GSM Network node with gateway remote readout via GSM yes 5 additional unit loads 2000 WTX16 IP Network node with gateway remote readout via Ethernet yes 5 additional un...

Page 3: ...ay to store data of up to 2000 meters and to provide a possibility for remote readout via GSM or Ethernet The gateway has an additional M Bus master that can drive up to 5 additional external M Bus un...

Page 4: ...electrical connections are made The electronics section is identical for all types of network nodes It contains control ele ments of the network RESET MODE DISPLAY 1 2 3 4 6 7 11 10 8 9 5 1 Connector...

Page 5: ...y DC 3 6 V 2 Indication of mains supply red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 GSM only 5 RS232 interface for servicing 6 Connector for M bus service connectio...

Page 6: ...red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 MOD only 5 RS232 interface for servicing 6 Connector for M bus service connection 7 Anschluss f r M Bus 8 mains connect...

Page 7: ...It can also be started manually with the ACT26 service tool Installa tionsmode2 In installation mode the radio network will be built up automati cally Metering devices that transmit installation tele...

Page 8: ...The registration of the device takes place and search mode starts Delete from version 2 2 for example If an already registered IrDA capable metering device is connected in IrDA master mode it can be r...

Page 9: ...ss II Then the live L and neutral N conductors must be connected to terminal IN of the power pack Mains voltage must be in the range from AC 100 to 240 V 50 60 Hz There is no protective earth PE conne...

Page 10: ...for voice and data service SIM cards only sold for voice service or M2M service cannot be used For that purpose remove the upper section of the WTX16 GSM from the base Press the SIM card slightly in...

Page 11: ...tained Staff dealing with the product must be familiar with all potential hazards and maintenan ce measures in accordance with the instructions given in this document It must be possible to disconnect...

Page 12: ...cy of transmission 1 Permanent ambient temperature Transport and storage Operation 20 60 C 30 C recommended 0 55 C Weight 0 3 kg Dimensions 184 31 8 9 7 200 6 0 R 1 5 0 R 100 150 250 2 5 0 R 55 250 2...